Modbus smoke alarm smoke sensor RS485 485 smoke sensor
Modbus smoke alarm smoke sensor RS485 485 smoke sensor

Modbus smoke alarm smoke sensor RS485 485 smoke sensor

Category:

Security/Anti theft and alarm equipment/Other anti-theft and alarm equipment and systems

Model:

JTY-GD-HA821-485

Brand:

Hongsheng High Tech

model:

JTY-GD-HA821-485

type:

Internet connected smoke detector

working power supply:

24V

alarm method:

signal transmission

Protection area:

60 square meters

ambient humidity:

95%

ambient temperature:

-10+50

Retail Price

666.00USD


重量

kg

  • Product Description
  • model

    JTY-GD-HA821-485

    type

    Internet connected smoke detector

    working power supply

    24V

    alarm method

    signal transmission

    Protection area

    60 square meters

    ambient humidity

    95%

    ambient temperature

    -10+50

    Description :

      Product Overview

      The JTY-GD-HA821-485 photoelectric smoke and fire detection alarm (hereinafter referred to as the alarm) can detect the smoke generated during a fire. The alarm adopts photoelectric smoke sensing devices and excellent production technology, with stable operation, beautiful appearance, simple installation, and no need for debugging. It can be widely used in shopping malls, hotels, shops, warehouses, computer rooms, residential areas and other places for fire safety detection. The alarm is equipped with a built-in buzzer, which can emit a strong sound after sounding an alarm. The alarm adopts standard 485 signal output, Modbus protocol, and supports secondary development.

      Features

      ● Power off/automatic reset optional

      ● Infrared photoelectric sensor

      ● Intelligent logic control, filtering out various false alarms ● Networked output/LED indicator alarms ● SMT process manufacturing, strong stability

      Dustproof, insect proof, and anti white light interference design

      ● Execution standard: GB4715-2005,57-7

      Technical Specifications

      Working voltage: DC9-35V

      Sensitivity: 0.1-0.3dB/m

      Signal output: RS485

      Communication protocol: Modbus RTU

      Compliant with standard: GB4715-2005

      Working environment: -10 ℃~50 ℃, ≤ 95%, no condensation

      Standby current: 500uA (relay normally open)

      Alarm current: 10mA (relay normally closed)

      Alarm indication: The red LED is always on

      Sensor: Infrared photoelectric sensor

      Anti RF interference: 10MHz~1GHz 20V/m

      Coverage area: When the space height is between 6m and 12m, the protection area of a detector is 80m2 for general protection sites. When the space height is below 6m, the protection area is 60m2. The specific parameters should be based on the design specifications for fire automatic alarm systems GB 50116-98. Sensitivity level: Level 1

      Dimensions: 100 (diameter) * 48mm (height)

      Wiring Instructions

      The power input can be 10~30V. When wiring the 485 signal line, be careful not to connect wires A and B in reverse, and ensure that the addresses of multiple devices on the bus do not conflict.

      2. Connect the power and signal lines to the installation base, and install the detector on the base

      Red "and" black "represent non-polar input of DC power supply;

      Blue and yellow "are 485A (3 legs) and 485B (4 legs)

      Installation Instructions

      1. Use screws to fix the installation base plate to the ceiling.

      2. Align the positioning protrusion at the bottom of the detector with the positioning groove on the installation base

      Rotate clockwise to install the detector.

      Parameter Settings

      1. Select the correct COM port (check the COM port in "My Computer - Properties - Device Manager - Ports").

      2. Connect only one device separately and power it on. Click on the software's test baud rate, and the software will test the current device's baud rate and address. The default baud rate is 4800bit/s and the default address is 0x01.

      3. Modify the address and baud rate according to usage needs, and also query the current functional status of the device.

      4. If the test is unsuccessful, please recheck the equipment wiring and 485 driver installation