Modbus smoke alarm smoke sensor RS485 485 smoke sensor
Category:
Security/Anti theft and alarm equipment/Other anti-theft and alarm equipment and systems
Model:
JTY-GD-HA821-485
Brand:
Hongsheng High Tech
model:
JTY-GD-HA821-485
type:
Internet connected smoke detector
working power supply:
24V
alarm method:
signal transmission
Protection area:
60 square meters
ambient humidity:
95%
ambient temperature:
-10+50
Retail Price
666.00USD
重量
kg
- Product Description
-
model JTY-GD-HA821-485
type Internet connected smoke detector
working power supply 24V
alarm method signal transmission
Protection area 60 square meters
ambient humidity 95%
ambient temperature -10+50
Description :
Product Overview
The JTY-GD-HA821-485 photoelectric smoke and fire detection alarm (hereinafter referred to as the alarm) can detect the smoke generated during a fire. The alarm adopts photoelectric smoke sensing devices and excellent production technology, with stable operation, beautiful appearance, simple installation, and no need for debugging. It can be widely used in shopping malls, hotels, shops, warehouses, computer rooms, residential areas and other places for fire safety detection. The alarm is equipped with a built-in buzzer, which can emit a strong sound after sounding an alarm. The alarm adopts standard 485 signal output, Modbus protocol, and supports secondary development.
Features
● Power off/automatic reset optional
● Infrared photoelectric sensor
● Intelligent logic control, filtering out various false alarms ● Networked output/LED indicator alarms ● SMT process manufacturing, strong stability
Dustproof, insect proof, and anti white light interference design
● Execution standard: GB4715-2005,57-7
Technical Specifications
Working voltage: DC9-35V
Sensitivity: 0.1-0.3dB/m
Signal output: RS485
Communication protocol: Modbus RTU
Compliant with standard: GB4715-2005
Working environment: -10 ℃~50 ℃, ≤ 95%, no condensation
Standby current: 500uA (relay normally open)
Alarm current: 10mA (relay normally closed)
Alarm indication: The red LED is always on
Sensor: Infrared photoelectric sensor
Anti RF interference: 10MHz~1GHz 20V/m
Coverage area: When the space height is between 6m and 12m, the protection area of a detector is 80m2 for general protection sites. When the space height is below 6m, the protection area is 60m2. The specific parameters should be based on the design specifications for fire automatic alarm systems GB 50116-98. Sensitivity level: Level 1
Dimensions: 100 (diameter) * 48mm (height)
Wiring Instructions
The power input can be 10~30V. When wiring the 485 signal line, be careful not to connect wires A and B in reverse, and ensure that the addresses of multiple devices on the bus do not conflict.
2. Connect the power and signal lines to the installation base, and install the detector on the base
Red "and" black "represent non-polar input of DC power supply;
Blue and yellow "are 485A (3 legs) and 485B (4 legs)
Installation Instructions
1. Use screws to fix the installation base plate to the ceiling.
2. Align the positioning protrusion at the bottom of the detector with the positioning groove on the installation base
Rotate clockwise to install the detector.
Parameter Settings
1. Select the correct COM port (check the COM port in "My Computer - Properties - Device Manager - Ports").
2. Connect only one device separately and power it on. Click on the software's test baud rate, and the software will test the current device's baud rate and address. The default baud rate is 4800bit/s and the default address is 0x01.
3. Modify the address and baud rate according to usage needs, and also query the current functional status of the device.
4. If the test is unsuccessful, please recheck the equipment wiring and 485 driver installation



AfterSalesService :
Key words:- Smoke sensor RS485