IC card prepaid metering box, biomass power plant metering, smart heating network flowmeter for heating enterprises
Category:
Instrumentation/Flow meter/flowmeter
Model:
STR/WEB/V2.0
Brand:
Qingdao Zhiyuan Instrument
model:
STR/WEB/V2.0
principle:
Differential pressure flowmeter
purpose:
steam flow meter
Nominal Diameter:
DN15-2000
work pressure:
1.6MPa
Applicable Medium:
Gas, liquid, steam
Operating Temperature:
three hundred
measurement range:
seven thousand three hundred and thirty-six
accuracy class:
one
measurement accuracy:
one
Installation type:
flange connection
flow range:
four thousand five hundred and three
Processing & Customization:
yes
weight:
forty-four
Place of Origin:
Qingdao, China
manufacturer:
Qingdao Zhiyuan Instrument
Retail Price
3,719.00USD
重量
kg
- Product Description
-
model STR/WEB/V2.0
principle Differential pressure flowmeter
purpose steam flow meter
Nominal Diameter DN15-2000
work pressure 1.6MPa
Applicable Medium Gas, liquid, steam
Operating Temperature three hundred
measurement range seven thousand three hundred and thirty-six
accuracy class one
measurement accuracy one
Installation type flange connection
flow range four thousand five hundred and three
Processing & Customization yes
weight forty-four
Place of Origin Qingdao, China
manufacturer Qingdao Zhiyuan Instrument
Description :


Qingdao Hesheng Zhiyuan Automation System Co., Ltd. IC card prepaid metering boxMeasurement software follows standards:
Specification for Computer Software Quality Assurance Plan GB/T12505
General Technical Specifications for Microcontrollers GB/T9813-2000
GB 4728.1-85 "Symbols for Electrical Diagrams"
Standard for Intelligent Flow Display Instrument JJG1003-2016
Vortex Flow Meter JB/T9249-2015
Verification Regulations for Vortex Flowmeters JJG1029-2007
Verification Regulations for Differential Pressure Flowmeters JJG640-2016
Differential Pressure Flow Meter GB/T2624-2006
STR/WEB/V2.0IC card prepaid metering box, biomass power plant metering, smart heating network flowmeter for heating enterprisesThe heating network center continuously collects various variable information (instantaneous flow rate, cumulative flow rate, pressure, temperature, compensation density, power status, valve status, power-off/power on time, prepaid steam balance, settlement balance, instrument key parameters, programming times, etc.) from various meters through a static IP transmission network, and saves these data in a universal database for generating various tables, curves, making report judgments, and reminding responsible personnel to process information through the Duanxin platform (SMS report). If required by the customer, the software provides a communication interface to provide data to the MIS system for operators to read and query the data. The core of the RS485 wired data remote meter reading system for external steam prepayment is computer network and communication technology. Currently, the most commonly used communication methods include twisted pair cables, optical fibers, etc. The IC card prepayment system is an intelligent comprehensive energy management system that breaks the traditional energy management mode. The IC card prepaid system implements prepaid management for situations where charging is difficult, electricity bills are overdue, and there are many charges in many regions
Qingdao Hesheng Zhiyuan Automation System Co., LtdIC card prepaid metering box, biomass power plant metering, smart heating network flowmeter for heating enterprisestrain:
1. On site training: During the implementation of the project, the client must assign technical personnel to participate in the construction and operation debugging of the project. Our company's engineering and technical personnel will provide on-site guidance and practical training for your company's personnel during implementation, ensuring that the progress of the project is synchronized with personnel training. Before the system trial run, we will provide system training to the customer. Through training, the customer's operational staff will understand the basic principles and learn system operation and maintenance, including a basic understanding of the software and hardware systems of this project. The training content is as follows: a. Basic knowledge and system configuration of the system, b. Courses on system installation, inspection, troubleshooting, online coordination and maintenance, and application training of human-machine interface. 2. Factory training: Our company conducts regular training for technical personnel of users who use our products every year. At that time, we will provide in-depth explanations of the company's software, hardware, and heating network technology, and conduct on-site practice according to the conditions. At the same time, we will answer any questions that users may have in various systems.
3IC card prepaid metering boxThe permissions of the sub centers are limited to data monitoring and do not allow downward operations, ensuring the security of the system. The data of each sub center in the main center is fully synchronized and displayed in real time. Real time and historical curves can be combined with topographic maps and monitoring point distribution maps, using real-time or historical data of monitoring points to provide real-time data for management personnel and play a certain role in managing resources. In order to improve meter reading efficiency, meter reading performance, reduce meter reading workload, save manpower, material resources, and financial resources, enhance the role of electricity management inspection, fully utilize the intelligence and technology of the system, prevent steam theft and detect abnormal operating states
Qingdao Hesheng Zhiyuan Automation System Co., LtdIC card prepaid metering box, biomass power plant metering, smart heating network flowmeter for heating enterprisesTechnical specifications for measuring instrument stations: The measuring station is installed in the factory of the steam unit, with one set per unit, including intelligent flow integrator, 4G module, antenna, data cable, unboxing equipment, DC backup power supply (UPS), wall mounted instrument box, and power distribution system. All devices should have replaceability and universality. The above devices need to be integrated into one chassis, and the connections between devices have been integrated and debugged as a whole before leaving the factory; Protection level IP65. Adopt protective measures such as pressure-sensitive and TVS to deal with and solve potential accidents such as voltage fluctuations, vibrations, electromagnetics, and lightning strikes in the power grid.
Qingdao Hesheng Zhiyuan Automation System Co., Ltd
189 Hui Xin 5483 Same number 1481
Q:3438-5007-67
AfterSalesService :
Key words:- IC card prepaid metering box
More Products