Smart heating network technology system, pre charging of heating network, introduction of intelligent heating
Smart heating network technology system, pre charging of heating network, introduction of intelligent heating

Smart heating network technology system, pre charging of heating network, introduction of intelligent heating

Category:

Instrumentation/Flow meter/flowmeter

Model:

STR/WEB/V2.0

Brand:

Qingdao Zhiyuan Instrument

model:

STR/WEB/V2.0

principle:

Differential pressure flowmeter

purpose:

High flow flowmeter

Nominal Diameter:

DN15-2000

work pressure:

1.6MPa

Applicable Medium:

Gas, liquid, steam

Operating Temperature:

three hundred

measurement range:

five thousand and sixteen

accuracy class:

one

measurement accuracy:

one

Installation type:

flange connection

flow range:

eight thousand nine hundred and three

Processing & Customization:

yes

weight:

seventeen

Place of Origin:

Qingdao, China

manufacturer:

Qingdao Zhiyuan Instrument

Retail Price

8,119.00USD


重量

kg

  • Product Description
  • model

    STR/WEB/V2.0

    principle

    Differential pressure flowmeter

    purpose

    High flow flowmeter

    Nominal Diameter

    DN15-2000

    work pressure

    1.6MPa

    Applicable Medium

    Gas, liquid, steam

    Operating Temperature

    three hundred

    measurement range

    five thousand and sixteen

    accuracy class

    one

    measurement accuracy

    one

    Installation type

    flange connection

    flow range

    eight thousand nine hundred and three

    Processing & Customization

    yes

    weight

    seventeen

    Place of Origin

    Qingdao, China

    manufacturer

    Qingdao Zhiyuan Instrument

    Description :

    STR/WEB/V2.0Smart heating network technology system, pre charging of heating network, introduction of intelligent heatingThe heating network center continuously collects various variable information (instantaneous flow rate, cumulative flow rate, pressure, temperature, compensation density, power status, valve status, power-off/power on time, prepaid steam balance, settlement balance, instrument key parameters, programming times, etc.) from various meters through a static IP transmission network, and saves these data in a universal database for generating various tables, curves, making report judgments, and reminding responsible personnel to process information through the Duanxin platform (SMS report). If required by the customer, the software provides a communication interface to provide data to the MIS system for operators to read and query the data. The main functions of the steam prepayment management system are as follows: file management function (1) operator file: establish login username and password, and grant corresponding operation permissions. (2) Terminal profile: Information parameters for registering a terminal. (3) Meter file: Register information for all meters, system security permission setting function: Permission setting provides comprehensive security authentication, users cannot enter the system, and legitimate users can perform corresponding operations based on their permissions

    Qingdao Zhiyuan Instrument Intelligent Heating Network Technology SystemThe task undertaken by the metering station is to measure various operational parameters of the flow meter system on site. Measurement: Measure the instantaneous flow rate, pressure, and temperature signals of on-site sensors, perform compensation density calculations, and calculate the required cumulative flow rate according to algorithms. Collect on-site power status, valve status, power-off/power on time, prepaid steam balance, settlement balance, instrument parameter report information, programming times, etc., and package these data together with measurement information. Within the same time granted by GPS, transmit the data of each point to the GPRS/CDMA communication module through data lines. The RS485 wired data remote meter reading system combines computer technology, modern communication technology, network technology, and microelectronics technology. It is mainly a meter reading method that collects data through remote intelligent terminals and transmits the data to specific systems through wired networks, and completes other forms of operations in the system

    Qingdao Hesheng Zhiyuan Automation System Co., LtdPrepaid intelligent flow display instrument is an intelligent programmable instrument with high measurement accuracy, strong functions, simple operation, and good stability. By using flow meters, pressure and temperature transmitters, or platinum resistors together, a high-precision flow testing system can be formed. Moreover, this instrument provides RS485/232 serial communication interface and USB interface for remote data acquisition and control by computer.Qingdao Zhiyuan Instrument Intelligent Heating Network Technology SystemBased on the on-site conditions of the project, our design adopts a prepaid intelligent flow display instrument to achieve measurement and transmission of prepaid steam flow meters on a flow integrator. The on-site and central display parameters include instantaneous steam flow rate, cumulative steam flow rate, steam temperature, steam pressure, and steam balance.

    Smart heating network technology system, pre charging of heating network, introduction of intelligent heatingOperation and maintenance management: 1. Establish equipment ledger, record and provide equipment information, reflect the basic parameters, operation and maintenance history of equipment, provide necessary information for daily maintenance and management of equipment, and analyze and manage equipment life and inspection cycle based on the online operation status and equipment ledger of equipment. 2. The equipment ledger should include: basic equipment information, equipment technical specifications, equipment defect records, measurement equipment inspection records, equipment changes, equipment spare parts, equipment ledger queries, and other functions. 3. The seamless integration of equipment ledger and real-time system enables the static and dynamic information of online devices. 4. Defect management includes: defect registration through the inspection system, defect information flow (upgrading, downgrading, forwarding, extension, etc.), defect information statistics, etc; The processed defects are automatically archived in the corresponding equipment ledger, and the phenomena, causes, and defect elimination measures of the faults during the defect handling process can be archived in the equipment fault library. 5. The responsible department and person for defect review and handling can be defined in the system, and the reported defect information will be automatically transmitted to the department for personnel to verify the defects. For confirmed defects, a defect elimination process can be generated for processing.

      6. The heat network prepayment totalizer can automatically generate various production reports and user steam consumption statistical reports, so that the supervisor can timely grasp the thermal production situation, timely solve various problems encountered in production, calmly realize the centralized dispatching management of colleges and universities, change the passive management mode to the active management mode, and replace it with a new computer information management. Automatic fault reporting function: the monitoring point automatically reports the fault information to the monitoring center, and automatically prints the report information. The faults detected automatically include: communication failure of flow meter, 220V AC power outage, IC card failure, etc

      Qingdao Hesheng Zhiyuan Automation System Co., Ltd

      189 Hui Xin 5483 Same number 1481

      Q:3438-5007-67

    AfterSalesService :

    Key words:
    • Smart heating network technology system