principle:

ultrasonic flowmeter

purpose:

Corrosion resistant flowmeter

Nominal Diameter:

DN15-2000

work pressure:

1.6MPa

Applicable Medium:

Gas, liquid, steam

Operating Temperature:

three hundred

measurement range:

six thousand eight hundred and sixty-four

accuracy class:

one

measurement accuracy:

one

Installation type:

flange connection

flow range:

seven thousand four hundred and one

Processing & Customization:

yes

weight:

seventy-seven

Place of Origin:

Qingdao, China

manufacturer:

Qingdao Zhiyuan Instrument

Retail Price

8,321.00USD


重量

kg

  • Product Description
  • model

    STR/WEB/V2.0

    principle

    ultrasonic flowmeter

    purpose

    Corrosion resistant flowmeter

    Nominal Diameter

    DN15-2000

    work pressure

    1.6MPa

    Applicable Medium

    Gas, liquid, steam

    Operating Temperature

    three hundred

    measurement range

    six thousand eight hundred and sixty-four

    accuracy class

    one

    measurement accuracy

    one

    Installation type

    flange connection

    flow range

    seven thousand four hundred and one

    Processing & Customization

    yes

    weight

    seventy-seven

    Place of Origin

    Qingdao, China

    manufacturer

    Qingdao Zhiyuan Instrument

    Description :

    becauseSmart Heat Network Management PlatformThere is a significant time delay in heat transfer during operation. By predicting the load of the heat production unit, appropriate adjustments can be made to the heat production plan based on the specific heat needs of the network, thereby improving the thermal efficiency of the entire heating network system. The heating network system specification is a new type of heating network composed of a heating physical equipment network (a network composed of heat sources, heating networks, user systems, local display instruments, and control and regulation devices), a heating information Internet of Things (a network composed of sensors, data collection devices, data transmission devices, etc.), and an intelligent decision-making system based on an intelligent heating platform, referred to as the intelligent heating network. Intelligent heating is based on the heating physical equipment network and supported by the heating information Internet of Things. Through an intelligent decision-making system, it provides auxiliary decision-making support for operation and management personnel, forming a heating system form that reduces operating energy consumption while ensuring indoor comfort.

      Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart Heat Network Management PlatformSystem Introduction:

      1. Establishment of a prepaid steam metering management center;

      2. Installation, commissioning, and data transmission of 100 sets of prepaid steam metering equipment;

      3. 100 remote metering points are open for meter reading on the cloud platform of the thermal power plant. In the first phase, N metering points will be used, and the excess will be reserved for future expansion;

      4. According to the steam parameters provided by Party A, the rated pressure is 2.5Mpa, the upper temperature limit is 320 ℃, the working pressure is 1.2Mpa, and the working temperature is 300 ℃. This data is an important parameter for us to choose a flow meter.

      5. External steam charging management valve adjustment function 1: In manual mode, after inserting the equipment card, the valve opening can be adjusted through the keyboard. In automatic mode, after recharging, the valve will slowly open automatically. Equipped with remote control mode, the valve opening can be adjusted through the upper computer. If there is a gas flow meter on site, we do not need to use our flow integrator. We only need the on-site flow meter to have RS485 communication function. Based on the communication protocol of the meter, we will develop communication software and directly connect it to the IC card control instrument using RS485 cable

    STR/WEB/V2.0GPRS remote meter reading APP, online monitoring of superheated steam, intelligent heat network management platform integratorThe heating network center continuously collects various variable information (instantaneous flow rate, cumulative flow rate, pressure, temperature, compensation density, power status, valve status, power-off/power on time, prepaid steam balance, settlement balance, instrument key parameters, programming times, etc.) from various meters through a static IP transmission network, and saves these data in a universal database for generating various tables, curves, making report judgments, and reminding responsible personnel to process information through the Duanxin platform (SMS report). If required by the customer, the software provides a communication interface to provide data to the MIS system for operators to read and query the data. The smart heating comprehensive management RS485 wired data remote meter reading system combines computer technology, modern communication technology, network technology, and micro electric technology. It is mainly a meter reading method that collects data through remote intelligent terminals and transmits the data to specific systems through wired networks, and completes other forms of operations in the system. Data management function: Data browsing: historical data can be browsed separately, and these data can be deleted, queried, and printed. For example, information stored in the database can be browsed: meter readings, statistical data, curve data, event data, etc., and these data can be exported to generate corresponding reports for printing

    GPRS remote meter reading APP, online monitoring of superheated steam, intelligent heat network management platform integratorIt can also provide the user unit with greater regulation, control, and guarantee capabilities, ensuring that various secondary energy sources of the user unit can be fully supplied. It is very suitable for providing electricity, heating, and cooling to developing areas, commercial and residential areas, rural areas, pastoral areas, and mountainous areas, greatly reducing environmental pressure. In short, distributed energy systems can meet the needs of special occasions, provide possibilities for the comprehensive cascade utilization of energy, open up new directions for the utilization of renewable energy, and make outstanding contributions to improving energy utilization efficiency, enhancing safety, and addressing environmental pollution. This is also a very important advantage. The values of various measuring devices on the smart heating network management platform are currently mostly manually reported by operators on a shift by shift basis. This simple and repetitive work inevitably brings some problems, such as unsynchronized meter reading, large human errors, and high labor intensity. Manual meter reading has become an obstacle to the automation and informatization of data management in power plants. Therefore, the application of RS485 wired data remote meter reading system is necessary. The system security permission setting function provides complete security authentication, and users cannot enter the system. Legitimate users can perform corresponding operations according to their permissions. The inefficiency of manual meter reading lags behind manual management methods, which are easily affected by human factors, have poor real-time performance, low reliability, and low efficiency. It is difficult to detect on-site faults in a timely manner. Due to the inability to collect data from all meters at the same time, it is also difficult to measure and analyze pipe losses, and thus cannot effectively manage the heating network

      Qingdao Hesheng Zhiyuan Automation System Co., Ltd

      189 Hui Xin 5483 Same number 1481

      Q:3438-5007-67

    AfterSalesService :

    Key words:
    • Smart Heat Network Management Platform