Steam metering management terminal, IC card recharge management, intelligent heating management function
Category:
Instrumentation/Flow meter/flowmeter
Model:
STR/WEB/V2.0
Brand:
Qingdao Zhiyuan Instrument
model:
STR/WEB/V2.0
principle:
Variable area flowmeter
purpose:
Corrosion resistant flowmeter
Nominal Diameter:
DN15-2000
work pressure:
1.6MPa
Applicable Medium:
Gas, liquid, steam
Operating Temperature:
three hundred
measurement range:
five hundred and seventy-eight
accuracy class:
one
measurement accuracy:
one
Installation type:
flange connection
flow range:
four thousand four hundred and sixty-five
Processing & Customization:
yes
weight:
seventeen
Place of Origin:
Qingdao, China
manufacturer:
Qingdao Zhiyuan Instrument
Retail Price
3,681.00USD
重量
kg
- Product Description
-
model STR/WEB/V2.0
principle Variable area flowmeter
purpose Corrosion resistant flowmeter
Nominal Diameter DN15-2000
work pressure 1.6MPa
Applicable Medium Gas, liquid, steam
Operating Temperature three hundred
measurement range five hundred and seventy-eight
accuracy class one
measurement accuracy one
Installation type flange connection
flow range four thousand four hundred and sixty-five
Processing & Customization yes
weight seventeen
Place of Origin Qingdao, China
manufacturer Qingdao Zhiyuan Instrument
Description :

Steam metering management terminalOn site instrument installation:Steam metering management terminal, IC card recharge management, intelligent heating management functionInstalling a protective box on the primary measuring equipment of the pipeline can provide shelter from wind and rain, protect the equipment, and extend its service life; 2、 It can prevent unauthorized operation of measuring equipment. Any type of flow meter is not suitable for steam metering management terminals. Choosing a flow meter that is suitable for thermal user operating conditions is the rigorous method. For steam metering schemes, the mainstream schemes are divided into two types: vortex street type and differential pressure type. In the actual heating process, we will cooperate with your side to conduct on-site inspections to determine which flow meter is more suitable for use.
Qingdao Zhiyuan InstrumentSteam metering management terminalFunction Introduction:
1. Dynamic display of valve status, unboxing status, instantaneous flow rate, pressure, temperature, cumulative flow rate, etc. for each hot user, with different colors used to represent different statuses; When each user point is in normal state, it is displayed in blue. When the parameters exceed the limit, it is reported, or there is a fault, it is displayed in red and flashes, and information is synchronously sent to notify personnel; 2. Real time historical data and curves of flow rate, pressure, temperature, density, differential pressure, and frequency are displayed in the same coordinate system, and can be freely compared. The mouse follows and displays the current data, which is intuitive and easy to analyze; 3. The wireless meter reading system can directly add hot customers through the front-end webpage, with convenient and fast operation, sorted by number, and the order of customer arrangement can be freely adjusted; Provide detailed information on thermal units, establish maintenance information for measuring equipment, and facilitate management personnel to query the history and current status of instruments; 4. Automatically generate daily, monthly, annual, and report forms, and be able to print reports in real time. Reports can be made according to the requirements of the thermal company. 5. Thermal user management data system, including flow rate, pressure, temperature, upper and lower limit report settings, instrument current operating parameters, unit price, special policies, responsible person information, etc., to prevent users from modifying settings; 6. Multi level operation permissions for the heating management system in the park are set and controlled by administrators to prevent unauthorized operations by personnel at different levels;
Distributed energy systems, as energy supply centers serving the local area, directly face the needs of local users and are deployed near them. This simplifies the energy transmission process for users, reducing energy losses and transmission costs, and increasing the safety of energy supply for users. Due to its lack of large-scale and long-distance energy output mode, it mainly targets the energy needs of local users,Steam metering management terminalThe scale will be constrained by user demand, and compared to traditional centralized energy supply systems, it is of medium to small capacity. According to the actual situation where various meters are relatively concentrated, the low-level network of the system adopts RS485 bus. It has the characteristics of simple structure, low cost, and low wiring requirements. The inefficient and backward manual management method of manual meter reading is easily affected by human factors, with poor real-time performance, low reliability, and low efficiency. It cannot detect on-site faults in a timely manner. Due to the inability to collect data from all meters at the same time, it is also difficult to measure and analyze pipe losses, and thus cannot effectively manage the heating network. The active call function: that is, it can actively extract data from monitoring points on the server of the dispatch center at any time
As a new generation of energy supply model,Steam metering management terminal, IC card recharge management, intelligent heating management functionIt is a powerful supplement to centralized energy supply systems. With the development of economy and technology, especially the active application of renewable energy, users' energy demands have begun to diversify; With the development and maturity of different energy technologies, there are increasingly more technologies to choose from. Distributed energy systems, as an open energy system, are showing a trend towards multifunctionality, including multiple energy inputs and meeting multiple energy needs of users simultaneously. People's concepts are constantly changing, and new requirements are constantly being put forward for the energy system (reliability, economy, environmental protection, sustainable development, etc.). The new Qingdao Zhiyuan instrument steam metering management can better meet these requirements and achieve multiple functional goals by selecting appropriate technologies, optimizing and integrating the system. Display functions: instantaneous flow rate, cumulative flow rate, remaining air volume, differential pressure or frequency, pressure, temperature, valve position, etc. Prompt function: When the IC card is used incorrectly (when the IC card function does not match the operation being performed), the LCD screen displays a prompt message, the operation is invalid, and the fault is automatically reported. Function: The monitoring point automatically reports the fault information to the monitoring center and prints the report information automatically. The faults detected automatically include communication failures of flow meters, 220V AC power outages, IC card failures, etc. In the late 1980s and early 1990s, pilot work on automated meter reading systems began. Various power supply enterprises across the country have basically established wireless power load control systems. Although their main construction purpose is to control loads, they are gradually being used for reading electricity meters for large users
Qingdao Hesheng Zhiyuan Automation System Co., Ltd
189 Hui Xin 5483 Same number 1481
Q:3438-5007-67
AfterSalesService :
Key words:- Steam metering management terminal
More Products