Smart heating solution, external steam metering and charging, heating network supply for heating enterprises
Category:
Instrumentation/Flow meter/flowmeter
Model:
STR/WEB/V2.0
Brand:
Qingdao Zhiyuan Instrument
model:
STR/WEB/V2.0
principle:
Impeller flowmeter
purpose:
Multiphase flowmeter
Nominal Diameter:
DN15-2000
work pressure:
1.6MPa
Applicable Medium:
Gas, liquid, steam
Operating Temperature:
three hundred
measurement range:
six hundred and seventy-nine
accuracy class:
one
measurement accuracy:
one
Installation type:
flange connection
flow range:
seven thousand eight hundred and forty-seven
Processing & Customization:
yes
weight:
fifty-one
Place of Origin:
Qingdao, China
manufacturer:
Qingdao Zhiyuan Instrument
Retail Price
3,782.00USD
重量
kg
- Product Description
-
model STR/WEB/V2.0
principle Impeller flowmeter
purpose Multiphase flowmeter
Nominal Diameter DN15-2000
work pressure 1.6MPa
Applicable Medium Gas, liquid, steam
Operating Temperature three hundred
measurement range six hundred and seventy-nine
accuracy class one
measurement accuracy one
Installation type flange connection
flow range seven thousand eight hundred and forty-seven
Processing & Customization yes
weight fifty-one
Place of Origin Qingdao, China
manufacturer Qingdao Zhiyuan Instrument
Description :
Heating metering is still more inclined towards smart heating, which is a direction and a development trend. Now heating metering has stepped on a key point in the development of the heating industry towards smart heating. It has virtually promoted the development of the industry. It has played a role in promoting the development of the heating industry through cloud computing measures such as big data, the Internet of Things, and the Internet.Smart heating solutionUpload valve position, flow rate and other data, and the upper computer can set the reporting method arbitrarily. Flexible communication parameter settings: The communication address and baud rate of the prepaid controller can be set according to needs (address range: 1-128, baud rates: 2400, 4800, 9600). After the system is established, the value reading time of the meter is unified, changing the original 15-30 minutes of manual reading, achieving fairness in assessment while reducing personnel labor intensity. Reasonable allocation of resources such as personnel, finance, and materials improves efficiency and achieves economic benefits. System maintenance: communication settings, site settings, instrument settings, range settings, option settings, user management, permission settings, data initialization, password changes, network settings and other functions. The network settings are as follows: Users can make corresponding settings and changes according to their own company's actual situation. Lightning protection function: The box machine is equipped with lightning protection module, but the control box must be reliably grounded. Data management function: Data browsing: historical data can be browsed separately, and these data can be deleted, queried, and printed. For example, information stored in the database can be browsed, such as table readings, statistical data, curve data, event data, etc., and these data can be exported to generate corresponding reports for printing
Qingdao Zhiyuan InstrumentSmart heating solutionFunction Introduction:
1. Dynamic display of valve status, unboxing status, instantaneous flow rate, pressure, temperature, cumulative flow rate, etc. for each hot user, with different colors used to represent different statuses; When each user point is in normal state, it is displayed in blue. When the parameters exceed the limit, it is reported, or there is a fault, it is displayed in red and flashes, and information is synchronously sent to notify personnel; 2. Real time historical data and curves of flow rate, pressure, temperature, density, differential pressure, and frequency are displayed in the same coordinate system, and can be freely compared. The mouse follows and displays the current data, which is intuitive and easy to analyze; 3. The IC card prepaid metering box can directly add hot customers through the front-end webpage, with convenient and fast operation. It is sorted by number and can freely adjust the order of customer arrangement; Provide detailed information on thermal units, establish maintenance information for measuring equipment, and facilitate management personnel to query the history and current status of instruments; 4. Automatically generate daily, monthly, annual, and report forms, and be able to print reports in real time. Reports can be made according to the requirements of the thermal company. 5. Thermal user management data system, including flow rate, pressure, temperature, upper and lower limit report settings, instrument current operating parameters, unit price, special policies, responsible person information, etc., to prevent users from modifying settings; 6. Multi level operation permissions for smart heating energy management are set by administrators to prevent unauthorized operations by personnel at different levels;
Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart heating solution, external steam metering and charging, heating network supply for heating enterprisesReport function: When the remaining balance is insufficient, the system automatically reports in both directions. The system automatically reports when unpacking. After the power supply is cut off, the system automatically reports in both directions. At the same time, the built-in UPS power supply continues to provide power, and the measurement will not be interrupted after a power outage; Upload valve position, flow rate and other data, and the upper computer can set the reporting method arbitrarily. You can also choose to send it. It has an overdraft function, and the overdraft amount will be deducted immediately during the next recharge (this function has permission restrictions); The system can set the valve opening, automatically control the size of the valve, ensure that the flow rate does not exceed the limit, and measure; And upload the actual valve opening in real-time; Simultaneously equipped with a heating function to prevent steam from impacting the pipeline. Lightning protection function: The box machine is equipped with a lightning protection module, but the control box must be reliably grounded. Convenient recharge: When the recharge software writes an IC card, there is no need to manually convert it into gas volume. Simply enter the amount and the software will automatically calculate the gas volume based on the unit. Price management: Different gas prices can be set in the recharge software according to different users, and can be modified at any time.
Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart heating solution, external steam metering and charging, heating network supply for heating enterprisestrain:
1. On site training: During the implementation of the project, the client must assign technical personnel to participate in the construction and operation debugging of the project. Our company's engineering and technical personnel will provide on-site guidance and practical training for your company's personnel during implementation, ensuring that the progress of the project is synchronized with personnel training. Before the system trial run, we will provide system training to the customer. Through training, the customer's operational staff will understand the basic principles and learn system operation and maintenance, including a basic understanding of the software and hardware systems of this project. The training content is as follows: a. Basic knowledge and system configuration of the system, b. Courses on system installation, inspection, troubleshooting, online coordination and maintenance, and application training of human-machine interface. 2. Factory training: Our company conducts regular training for technical personnel of users who use our products every year. At that time, we will provide in-depth explanations of the company's software, hardware, and heating network technology, and conduct on-site practice according to the conditions. At the same time, we will answer any questions that users may have in various systems.
3Smart heating solutionSystem expansion and upgrade function: The system has an open data interface, which facilitates the addition and expansion of monitoring points in the later stage. After the establishment of the system, the value reading time of the meter has been unified, changing the 15-30 minute manual reading time, achieving fairness in assessment while reducing the labor intensity of personnel. Reasonable allocation of resources such as personnel, finance, and materials has improved efficiency and achieved economic benefits. In the late 1980s and early 1990s, the pilot work of automated meter reading system began. Various power supply enterprises across the country have basically established wireless power load control systems. Although their main construction purpose is to control loads, they are gradually being used for reading electricity meters for large users
Qingdao Hesheng Zhiyuan Automation System Co., Ltd
189 Hui Xin 5483 Same number 1481
Q:3438-5007-67
AfterSalesService :
Key words:- Smart heating solution
More Products