Heating intelligent heating network system, saturated steam metering, GPRS data acquisition method
Category:
Instrumentation/Flow meter/flowmeter
Model:
STR/WEB/V2.0
Brand:
Qingdao Zhiyuan Instrument
model:
STR/WEB/V2.0
principle:
Variable area flowmeter
purpose:
Liquid flowmeter
Nominal Diameter:
DN15-2000
work pressure:
1.6MPa
Applicable Medium:
Gas, liquid, steam
Operating Temperature:
three hundred
measurement range:
two thousand four hundred and sixty-four
accuracy class:
one
measurement accuracy:
one
Installation type:
flange connection
flow range:
nine thousand six hundred and thirty-one
Processing & Customization:
yes
weight:
fifty-seven
Place of Origin:
Qingdao, China
manufacturer:
Qingdao Zhiyuan Instrument
Retail Price
8,847.00USD
重量
kg
- Product Description
-
model STR/WEB/V2.0
principle Variable area flowmeter
purpose Liquid flowmeter
Nominal Diameter DN15-2000
work pressure 1.6MPa
Applicable Medium Gas, liquid, steam
Operating Temperature three hundred
measurement range two thousand four hundred and sixty-four
accuracy class one
measurement accuracy one
Installation type flange connection
flow range nine thousand six hundred and thirty-one
Processing & Customization yes
weight fifty-seven
Place of Origin Qingdao, China
manufacturer Qingdao Zhiyuan Instrument
Description :

Qingdao Hesheng Smart Heating Network Heating User Management: 1. Basic information management of heating users, including user name, number, person, method, pipe diameter and wall thickness, metering equipment form (vortex street, orifice plate, etc.), declared steam consumption, commonly used steam consumption, etc. 2. Analyze the proportion of key users in branch lines, main lines, and overall thermal users, and provide scheduling optimization suggestions based on historical data and other factors to assess the impact of key user start stop on corresponding pipeline parameters. 3. Analysis report on peak and valley flow of hot users, statistics on load situation, and analysis to assist in formulating business plans. 4. Comparative analysis of temperature, pressure, and flow curves of thermal users with similar pipelines and diameters to assist in identifying pipeline anomalies.fiveSmart heating network system for heatingGas and heat recharge, card insertion, and inquiry, with IC card technology, can be easily done with just one card, transforming the traditional manual meter reading and pricing process into user card based gas and heat purchase, achieving automation in the collection and management of gas and heating fees. The application of wireless remote intelligent meter reading system will realize fully automated meter reading, which can be regarded as one of the meter reading methods. It will gradually replace manual meter reading and semi-automatic meter reading methods to achieve real-time detection and management of water meters, real-time analysis of users' water, gas, and gas usage and conditions. The basic function is to recharge first, then use gas, and automatically close the valve when used up; Security: Three types of IC cards are used for management and operation, including equipment management card, user gas purchase card, and maintenance card; Cards and tables correspond one-to-one and cannot be used interchangeably. If the password verification fails three times in a row, the IC card will be locked and cannot be used for data writing operations
Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart heating network system for heatingGeneral function introduction:
System information management: database server parameter settings, communication server information settings, operator information management, password modification, industry category settings, system announcement information management. User Information Management: Regional Information Management, User Information Management, Measurement Point Information Management, and Meter Information Management. Flow monitoring management: New data monitoring of flow meters, supplementary recording of water meter data, monitoring of water meters: instantaneous flow, positive cumulative flow, negative cumulative flow. Inspection and repair management: flowmeter inspection management, water meter repair management. Data query management: user information query, measurement point information query, water and gas situation query, report information query, operation log query, historical data query. Statistical report generation: Generate reports by hour, day, week, ten day, month, year, and other time periods, and generate water usage details by year, month, and day. Usage analysis curve: Plot the water usage data of each station's flow meter into hourly, daily, ten day, monthly, annual and other time periods.
Qingdao Zhiyuan InstrumentHeating intelligent heating network system, saturated steam metering, GPRS data acquisition methodFeatures: 1. Based on GPRS or CDMA wireless networks, large-scale pipeline operation status monitoring is achieved, saving users expensive network construction and maintenance costs, high real-time performance, and low networking costs; 2. Rich and authentic monitoring information, fast system response speed; 3. Large capacity database, no worries about storing historical data; 4. Multiple sub centers support GPRS access for convenient user management; 5. Highly reliable industrial grade design, easy to maintain; 6. Significant economic and social benefits, with low operating costs; 7. System Scalability: The system should have powerful expansion capabilities, allowing for the addition of users at any time, including hard copy functionality, report printing functionality, and computing tool functionality.
Qingdao Hesheng Zhiyuan Automation System Co., LtdHeating intelligent heating network system, saturated steam metering, GPRS data acquisition methodtrain:
1. On site training: During the implementation of the project, the client must assign technical personnel to participate in the construction and operation debugging of the project. Our company's engineering and technical personnel will provide on-site guidance and practical training for your company's personnel during implementation, ensuring that the progress of the project is synchronized with personnel training. Before the system trial run, we will provide system training to the customer. Through training, the customer's operational staff will understand the basic principles and learn system operation and maintenance, including a basic understanding of the software and hardware systems of this project. The training content is as follows: a. Basic knowledge and system configuration of the system, b. Courses on system installation, inspection, troubleshooting, online coordination and maintenance, and application training of human-machine interface. 2. Factory training: Our company conducts regular training for technical personnel of users who use our products every year. At that time, we will provide in-depth explanations of the company's software, hardware, and heating network technology, and conduct on-site practice according to the conditions. At the same time, we will answer any questions that users may have in various systems.
3Smart heating network system for heatingWith the continuous development of urban construction and the continuous expansion of hot water, steam, tap water, gas and other supply areas, the traditional manual meter reading method can no longer meet the requirements of enterprises for cost recovery, instrument operation and the construction of digital management technology platform. The gprs remote meter reading system is a management system integrating microcomputer technology, network technology, communication technology and automatic measurement technology, and can automatically generate various production reports and user steam consumption statistical reports, so that supervisors can timely grasp the thermal production situation, timely solve various problems encountered in production, calmly realize the centralized dispatching management of colleges and universities, change the past passive management mode into active management mode, and replace it with new computer information management
Qingdao Hesheng Zhiyuan Automation System Co., Ltd
189 Hui Xin 5483 Same number 1481
Q:3438-5007-67
AfterSalesService :
Key words:- Smart heating network system for heating
More Products