Smart heating system application, tap water meter reading system, smart heating network system for thermal power plants
Category:
Instrumentation/Flow meter/flowmeter
Model:
STR/WEB/V2.0
Brand:
Qingdao Zhiyuan Instrument
model:
STR/WEB/V2.0
principle:
ultrasonic flowmeter
purpose:
Micro flow flowmeter
Nominal Diameter:
DN15-2000
work pressure:
1.6MPa
Applicable Medium:
Gas, liquid, steam
Operating Temperature:
three hundred
measurement range:
seven thousand six hundred and forty-one
accuracy class:
one
measurement accuracy:
one
Installation type:
flange connection
flow range:
four thousand eight hundred and eight
Processing & Customization:
yes
weight:
six
Place of Origin:
Qingdao, China
manufacturer:
Qingdao Zhiyuan Instrument
Retail Price
744.00USD
重量
kg
- Product Description
-
model STR/WEB/V2.0
principle ultrasonic flowmeter
purpose Micro flow flowmeter
Nominal Diameter DN15-2000
work pressure 1.6MPa
Applicable Medium Gas, liquid, steam
Operating Temperature three hundred
measurement range seven thousand six hundred and forty-one
accuracy class one
measurement accuracy one
Installation type flange connection
flow range four thousand eight hundred and eight
Processing & Customization yes
weight six
Place of Origin Qingdao, China
manufacturer Qingdao Zhiyuan Instrument
Description :

Qingdao Hesheng CompanySmart heating system application, tap water meter reading system, smart heating network system for thermal power plantsSmart Decision Analysis: Customize reports based on the needs of the company's management decision-makers, and provide targeted analysis to assist in business decision-making. 1. Real time and historical data collection and analysis of total steam supply and consumption; 2. Analysis of year-on-year and month on month data on total steam supply, steam consumption, various branch lines, and heat users; 3. Analyze the year-on-year and month on month data of steam consumption of heat users by industry, and analyze the proportion of steam consumption in each industry in the heating network; At the same time, based on the impact of market conditions on the industry and the historical situation of industry gas consumption, analyze the changes in gas consumption in the future period.4. The energy consumption analysis system can calculate the energy consumption of heat sources, comprehensive energy consumption of heating, and energy consumption of pipeline losses. At the same time, it provides a large number of analysis models and tools, which can compare the energy consumption of the same period in the history of the enterprise, as well as compare it with the same enterprise. 5. Standard data storage and backup function for smart heating network system: The system database can be stored locally, and its storage time is determined by demand and computer configuration. The IC card prepaid flowmeter also has RS485 communication to achieve remote data transmission and valve adjustment functions
Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart heating system application, tap water meter reading system, smart heating network system for thermal power plantsSystem functions:
a. Can query historical data of any hot user, any parameter, and any time period, and support the export and printing functions of statistical reports and analysis curves; Rich report customization printing and archiving functions, which can print hot user daily, monthly, and steam consumption detail reports, parent pipe daily, monthly, and summary reports, and can be archived as EXCEL format files (*. xls). b. Hot user management data system, including flow rate, pressure, temperature, upper and lower limit report settings, current operating parameters of instruments, unit price, special policies, responsible person information, etc., to prevent users from modifying settings; c. Access control function: Operators need to apply for a login name with their personal ID when logging in (non ID cannot be applied for), and achieve real name login; After entering the password and passing the identity verification, the system can enter. The system defines access permissions according to different access users. d. The smart heating network adopts a B/S structure for centralized heating, supporting intelligent terminals with internet access functions to access it anytime, anywhere, and achieve mobile office operation of the heating network; e. Geographical distribution map of heating network users and routing map of heating network pipelines, which can be drawn according to the needs of the network and marked with steam flow direction (green line in the figure), locate the coordinate points of heating network users, and display the pipeline distance between heating customers and heat sources;
f. Smart heating system application display functions: instantaneous flow rate, cumulative flow rate, remaining air volume, differential pressure or frequency, pressure, temperature, valve position, etc. Reminder function: When the IC card is used incorrectly (when the IC card function does not match the operation being performed), the LCD screen displays a prompt message, and the operation is invalid. Traditional meter reading methods are easily affected by factors such as weather conditions and errors or omissions. However, the intelligent meter reading system directly eliminates the unstable step of manual operation. Therefore, with the help of this system, the cost of hot water and steam meters can be calculated. Overdraft function: You can choose the "overdraft" function. For individual special users, they are allowed to have a certain overdraft limit. In the event that the user's balance is exhausted, the valve will not be closed, and a certain amount of steam can be overdrawn for use
Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart heating system application, tap water meter reading system, smart heating network system for thermal power plantsReport function: When the remaining balance is insufficient, the system automatically reports in both directions. The system automatically reports when unpacking. After the power supply is cut off, the system automatically reports in both directions. At the same time, the built-in UPS power supply continues to provide power, and the measurement will not be interrupted after a power outage; Upload valve position, flow rate and other data, and the upper computer can set the reporting method arbitrarily. You can also choose to send it. It has an overdraft function, and the overdraft amount will be deducted immediately during the next recharge (this function has permission restrictions); The system can set the valve opening, automatically control the size of the valve, ensure that the flow rate does not exceed the limit, and measure; And upload the actual valve opening in real-time; Simultaneously equipped with a heating function to prevent steam from impacting the pipeline. Lightning protection function: The box machine is equipped with a lightning protection module, but the control box must be reliably grounded. Convenient recharge: When the recharge software writes an IC card, there is no need to manually convert it into gas volume. Simply enter the amount and the software will automatically calculate the gas volume based on the unit. Price management: Different gas prices can be set in the recharge software according to different users, and can be modified at any time.
Qingdao Hesheng Zhiyuan Automation System Co., LtdApplication of Smart Heating SystemGeneral function introduction:
System information management: database server parameter settings, communication server information settings, operator information management, password modification, industry category settings, system announcement information management. User Information Management: Regional Information Management, User Information Management, Measurement Point Information Management, and Meter Information Management. Flow monitoring management: New data monitoring of flow meters, supplementary recording of water meter data, monitoring of water meters: instantaneous flow, positive cumulative flow, negative cumulative flow. Inspection and repair management: flowmeter inspection management, water meter repair management. Data query management: user information query, measurement point information query, water and gas situation query, report information query, operation log query, historical data query. Statistical report generation: Generate reports by hour, day, week, ten day, month, year, and other time periods, and generate water usage details by year, month, and day. Usage analysis curve: Plot the water usage data of each station's flow meter into hourly, daily, ten day, monthly, annual and other time periods.
Qingdao Hesheng Zhiyuan Automation System Co., Ltd
189 Hui Xin 5483 Same number 1481
Q:3438-5007-67
AfterSalesService :
Key words:- Application of Smart Heating System
More Products