Smart heating system application, external network steam supply card recharge, smart heating network technology function
Smart heating system application, external network steam supply card recharge, smart heating network technology function

Smart heating system application, external network steam supply card recharge, smart heating network technology function

Category:

Instrumentation/Flow meter/flowmeter

Model:

STR/WEB/V2.0

Brand:

Qingdao Zhiyuan Instrument

model:

STR/WEB/V2.0

principle:

Differential pressure flowmeter

purpose:

gas flow meter

Nominal Diameter:

DN15-2000

work pressure:

1.6MPa

Applicable Medium:

Gas, liquid, steam

Operating Temperature:

three hundred

measurement range:

seven thousand five hundred and fifty-one

accuracy class:

one

measurement accuracy:

one

Installation type:

flange connection

flow range:

four thousand seven hundred and eighteen

Processing & Customization:

yes

weight:

twenty-four

Place of Origin:

Qingdao, China

manufacturer:

Qingdao Zhiyuan Instrument

Retail Price

3,934.00USD


重量

kg

  • Product Description
  • model

    STR/WEB/V2.0

    principle

    Differential pressure flowmeter

    purpose

    gas flow meter

    Nominal Diameter

    DN15-2000

    work pressure

    1.6MPa

    Applicable Medium

    Gas, liquid, steam

    Operating Temperature

    three hundred

    measurement range

    seven thousand five hundred and fifty-one

    accuracy class

    one

    measurement accuracy

    one

    Installation type

    flange connection

    flow range

    four thousand seven hundred and eighteen

    Processing & Customization

    yes

    weight

    twenty-four

    Place of Origin

    Qingdao, China

    manufacturer

    Qingdao Zhiyuan Instrument

    Description :

    Application of Qingdao Hesheng Zhiyuan Smart Heating SystemPrinciples of Measurement Software Design:

      The system design follows the basic principles of "mature technology, real-time and fast, safe and reliable, economical and practical, easy to expand, and easy to upgrade".

      2. The on-site measuring instrument technology meets the standard design, and adopts computer remote mode or assisted management mode.

      3. Adopting a mature fully open, layered, and fully distributed system structure, the system configuration and equipment selection facilitate the expansion of hardware and functionality, and adapt to the rapid development of computer technology. By fully utilizing the technology in the computer field, the system performance can reach the domestic level, ensuring the safety and reliability of software and hardware, and long-term continuous operation, in order to achieve the goal of "unmanned and few people on duty".

      4. The main network topology of the system adopts DDN network to enable communication between each station system and the central workstation, realizing data monitoring and functions. Information publishing is achieved through IE browsing through WEB Server, supporting remote access by intelligent terminals.

      fiveSmart heating system application, external network steam supply card recharge, smart heating network technology functionValve regulation function 2: Over flow limiting function, which automatically reduces the valve opening when the flow exceeds the set value. The small flow valve closing function automatically closes the valve when the flow rate remains below the set value for a period of time. Query and statistics: It can query and display data for each instrument at any time during a certain period of time, making it easy to assess and query each shift. Display functions include instantaneous flow rate, cumulative flow rate, remaining gas volume, differential pressure or frequency, pressure, temperature, valve position, etc. Prompt function: When the IC card is used incorrectly (when the IC card function does not match the operation being performed), the LCD screen displays a prompt message, and the operation is invalid

    Smart heating system application, external network steam supply card recharge, smart heating network technology functionPartial Function Introduction:

      The data analysis function includes steam analysis of the sum of total table and settlement flow, steam analysis of settlement flow of each sub table and branch line, represented in the form of curves and reports, and can automatically generate pipe losses for each pipeline;

      The system software adopts a networked design, supporting multiple network interfaces and remote browsing. After running the program on the server side, the screen will be published, and various data can be shared by other departments of the thermal power plant through the IE browser. The system has communication function with the power plant MIS system and can transmit the heat network signal to the upper information management system;

      The centralized water supply management platform supports large screen projection function, which can send geographic graphics, data, curves, pipeline diagrams, etc. displayed on the computer to the large screen, making the system have good visibility;

      The design of system software and hardware can facilitate future expansion, upgrading, and transformation; The hardware adopts modular design, which is convenient for transformation and upgrading.

      Equipped with operation logs, it can query the operation process and modify parameters of each customer, achieve traceable and orderly supervision, and avoid operational errors that cannot be traced

    Application of Smart Heating SystemThe application of wireless remote intelligent meter reading system will achieve fully automated meter reading, which can be regarded as one of the meter reading methods. It will gradually replace manual meter reading and semi-automatic meter reading methods to achieve real-time detection and management of water meters, real-time analysis of users' water, gas, gas and other quantities and conditions. The remote meter reading system replaces the traditional manual meter reading method with fully automated meter reading, solving the problem of low efficiency of manual meter reading. Compared with similar meter reading systems, it is completely based on the popularization and application of the Internet of Things technology, and uses a pan tilt system architecture, which enables the system to have remote debugging, remote maintenance, and data exchange functions with external third-party software. Currently, the values of various measuring devices are mostly manually read by operators on a shift by shift basis. This simple and repetitive work inevitably brings some problems, such as unsynchronized meter reading, large human errors, and high labor intensity. Manual meter reading has become an obstacle to the automation and informatization of data management in power plants. Therefore, the application of RS485 wired data remote meter reading system is necessary

    Smart heating system application, external network steam supply card recharge, smart heating network technology functionThe gradually established thermal user management system includes thermal user data, such as industry classification, gas usage characteristics (intermittent, continuous), and gas usage periods. Through analysis of thermal user data, it guides thermal users to develop reasonable steam usage plans and promotes the day night balance of the total heating load provided by the bidding party; In addition, by understanding the management of heating users and analyzing the possible fluctuations in steam load caused by market and industry influences on heating users in the future, the total steam supply load of the bidding party can be predicted and corresponding steam supply plans can be formulated.

      Qingdao Hesheng Smart Heating Network Heating User Management: 1. Basic information management of heating users, including user name, number, person, method, pipe diameter and wall thickness, metering equipment form (vortex street, orifice plate, etc.), declared steam consumption, commonly used steam consumption, etc. 2. Analyze the proportion of key users in branch lines, main lines, and overall thermal users, and provide scheduling optimization suggestions based on historical data and other factors to assess the impact of key user start stop on corresponding pipeline parameters. 3. Analysis report on peak and valley flow of hot users, statistics on load situation, and analysis to assist in formulating business plans. 4. Comparative analysis of temperature, pressure, and flow curves of thermal users with similar pipelines and diameters to assist in identifying pipeline anomalies.

      fiveApplication of Smart Heating SystemUpload valve position, flow rate and other data, and the upper computer can set the reporting method arbitrarily. Flexible communication parameter settings: The communication address and baud rate of the prepaid controller can be set as needed (address range: 1-128, baud rates: 2400, 4800, 9600). The IC card prepaid system consists of a prepaid control box; Explosion proof (explosion-proof) electric control valve; Card reader/writer (including recharge software); Items 1, 2, and 3 are installed at the on-site measurement point, while item 3 is installed on the office computer of the management personnel. Communication function: Provides RS485 communication interface, which can be connected through wired, GPRS/CDMA and other methods, using standard Modbus RTU protocol.

      Qingdao Hesheng Zhiyuan Automation System Co., Ltd

      189 Hui Xin 5483 Same number 1481

      Q:3438-5007-67

    AfterSalesService :

    Key words:
    • Application of Smart Heating System