Heating enterprise charging plan, online monitoring of thermal power plants, and pre charging system platform for heating networks
Heating enterprise charging plan, online monitoring of thermal power plants, and pre charging system platform for heating networks

Heating enterprise charging plan, online monitoring of thermal power plants, and pre charging system platform for heating networks

Category:

Instrumentation/Flow meter/flowmeter

Model:

STR/WEB/V2.0

Brand:

Qingdao Zhiyuan Instrument

model:

STR/WEB/V2.0

principle:

Variable area flowmeter

purpose:

Multiphase flowmeter

Nominal Diameter:

DN15-2000

work pressure:

1.6MPa

Applicable Medium:

Gas, liquid, steam

Operating Temperature:

three hundred

measurement range:

seven thousand nine hundred and sixty

accuracy class:

one

measurement accuracy:

one

Installation type:

flange connection

flow range:

five thousand one hundred and twenty-seven

Processing & Customization:

yes

weight:

fifty-nine

Place of Origin:

Qingdao, China

manufacturer:

Qingdao Zhiyuan Instrument

Retail Price

1,063.00USD


重量

kg

  • Product Description
  • model

    STR/WEB/V2.0

    principle

    Variable area flowmeter

    purpose

    Multiphase flowmeter

    Nominal Diameter

    DN15-2000

    work pressure

    1.6MPa

    Applicable Medium

    Gas, liquid, steam

    Operating Temperature

    three hundred

    measurement range

    seven thousand nine hundred and sixty

    accuracy class

    one

    measurement accuracy

    one

    Installation type

    flange connection

    flow range

    five thousand one hundred and twenty-seven

    Processing & Customization

    yes

    weight

    fifty-nine

    Place of Origin

    Qingdao, China

    manufacturer

    Qingdao Zhiyuan Instrument

    Description :

      Qingdao Hesheng Zhiyuan Automation System Co., LtdCharging Scheme for Heating EnterprisesEquipped with RS232/RS485 standard communication interface and MODBUS RTU, MODBUS ASC Ⅱ industrial standard communication protocol, it can communicate with intelligent flow meters, read various measurement parameters and working parameters in intelligent flow meters.

      1. The device has automatic dialing and disconnection redialing functions. When the network condition is unstable, it has the ability to automatically restore communication, ensuring stable system operation without human intervention; When the signal in the area is weak, the module can communicate normally by changing the signal reception and transmission strength of the module.

      2. Online query function can be achieved through the Internet, and users only need to provide their username and password. The real-time online query function can be completed.

      3. Equipped with data cable and 12VDC power supply.Heating enterprise charging plan, online monitoring of thermal power plants, and pre charging system platform for heating networksAt present, there are many technologies used for meter reading in China, such as manual meter reading, RS485 bus, infrared and wireless data remote transmission, etc. Among them, GPRS wireless data remote transmission and RS485 bus meter reading technologies are relatively mature and widely adopted. Data recovery function: In the event of accidental damage to the control instrument, internal data (mainly user recharge balance) can be restored, effectively avoiding the occurrence of both parties. Valve closing function: After the purchase of steam is used up, the valve will automatically close. The valve closing action can be set according to the actual situation, such as closing 50%, 40%, or 30%, and the specific value is set by the user themselves. Power outage protection function: Original data can be saved for ten years in the event of a power outage

      Qingdao Hesheng Zhiyuan Automation System Co., LtdCharging Scheme for Heating EnterprisesGeneral function introduction:

      System information management: database server parameter settings, communication server information settings, operator information management, password modification, industry category settings, system announcement information management. User Information Management: Regional Information Management, User Information Management, Measurement Point Information Management, and Meter Information Management. Flow monitoring management: New data monitoring of flow meters, supplementary recording of water meter data, monitoring of water meters: instantaneous flow, positive cumulative flow, negative cumulative flow. Inspection and repair management: flowmeter inspection management, water meter repair management. Data query management: user information query, measurement point information query, water and gas situation query, report information query, operation log query, historical data query. Statistical report generation: Generate reports by hour, day, week, ten day, month, year, and other time periods, and generate water usage details by year, month, and day. Usage analysis curve: Plot the water usage data of each station's flow meter into hourly, daily, ten day, monthly, annual and other time periods.

      Application of Qingdao STR/WEB/V2.0 Qingdao Zhiyuan Instrument Intelligent Heating System: Charging Scheme for Heating EnterprisesThe main application is to achieve intelligence and ensure thermal balance of heat source output. Install temperature, pressure, flow and other sensors at each heat source unit and pipeline outlet to calculate the energy consumption of each link, display information on inlet and outlet temperature, pressure, flow and other aspects. The sensors will send the collected information to the heating dispatch center to achieve real-time monitoring of various parameter information.Heating enterprise charging plan, online monitoring of thermal power plants, and pre charging system platform for heating networksIn the application of heat source, it is also necessary to monitor load and weather changes, combine specific weather and load conditions, adhere to the principle of economic operation, compare the required heat with the heating amount, draw the trend curve of changes, and judge whether to start or stop the furnace. This will meet the heat needs of users without energy waste and save heating costs.

    Heating enterprise charging plan, online monitoring of thermal power plants, and pre charging system platform for heating networksPartial Function Introduction:

      The data analysis function includes steam analysis of the sum of total table and settlement flow, steam analysis of settlement flow of each sub table and branch line, represented in the form of curves and reports, and can automatically generate pipe losses for each pipeline;

      The system software adopts a networked design, supporting multiple network interfaces and remote browsing. After running the program on the server side, the screen will be published, and various data can be shared by other departments of the thermal power plant through the IE browser. The system has communication function with the power plant MIS system and can transmit the heat network signal to the upper information management system;

      The heating enterprise management system supports large screen projection function, which can send geographic graphics, data, curves, pipeline diagrams, etc. displayed on the computer to the large screen, making the system have good visibility;

      The design of system software and hardware can facilitate future expansion, upgrading, and transformation; The hardware adopts modular design, which is convenient for transformation and upgrading.

      Equipped with operation logs, it can query the operation process and modify parameters of each customer, achieve traceable and orderly supervision, and avoid operational errors that cannot be traced

    Charging Scheme for Heating EnterprisesThe wired data acquisition system is based on the RS485 bus. The RS485 wired data remote meter reading system is a system that uses modern communication and computer network technology to automatically capture remote data. The data capture function is implemented by the main station to centrally capture meter readings. Automatically collect meter data and other information from the concentrator according to the set reading interval and reading cycle, and have real-time random calling and address selection functions. Equipment operation and parameter modification must be done with a device card inserted, which is more reliable than password protection

      Qingdao Hesheng Zhiyuan Automation System Co., Ltd

      189 Hui Xin 5483 Same number 1481

      Q:3438-5007-67

    AfterSalesService :

    Key words:
    • Charging Scheme for Heating Enterprises