Smart heating network energy conservation and emission reduction, thermal network recharge management, smart heating energy-saving application
Category:
Instrumentation/Flow meter/flowmeter
Model:
STR/WEB/V2.0
Brand:
Qingdao Zhiyuan Instrument
model:
STR/WEB/V2.0
principle:
Fluid oscillating flowmeter
purpose:
Micro flow flowmeter
Nominal Diameter:
DN15-2000
work pressure:
1.6MPa
Applicable Medium:
Gas, liquid, steam
Operating Temperature:
three hundred
measurement range:
six hundred and eighty-three
accuracy class:
one
measurement accuracy:
one
Installation type:
flange connection
flow range:
four thousand five hundred and seventy
Processing & Customization:
yes
weight:
thirty-one
Place of Origin:
Qingdao, China
manufacturer:
Qingdao Zhiyuan Instrument
Retail Price
3,786.00USD
重量
kg
- Product Description
-
model STR/WEB/V2.0
principle Fluid oscillating flowmeter
purpose Micro flow flowmeter
Nominal Diameter DN15-2000
work pressure 1.6MPa
Applicable Medium Gas, liquid, steam
Operating Temperature three hundred
measurement range six hundred and eighty-three
accuracy class one
measurement accuracy one
Installation type flange connection
flow range four thousand five hundred and seventy
Processing & Customization yes
weight thirty-one
Place of Origin Qingdao, China
manufacturer Qingdao Zhiyuan Instrument
Description :

Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart heating network energy conservation and emission reduction, thermal network recharge management, smart heating energy-saving applicationtrain:1. On site training: During the implementation of the project, the client must assign technical personnel to participate in the construction and operation debugging of the project. Our company's engineering and technical personnel will provide on-site guidance and practical training for your company's personnel during implementation, ensuring that the progress of the project is synchronized with personnel training. Before the system trial run, we will provide system training to the customer. Through training, the customer's operational staff will understand the basic principles and learn system operation and maintenance, including a basic understanding of the software and hardware systems of this project. The training content is as follows: a. Basic knowledge and system configuration of the system, b. Courses on system installation, inspection, troubleshooting, online coordination and maintenance, and application training of human-machine interface. 2. Factory training: Our company conducts regular training for technical personnel of users who use our products every year. At that time, we will provide in-depth explanations of the company's software, hardware, and heating network technology, and conduct on-site practice according to the conditions. At the same time, we will answer any questions that users may have in various systems.
3Smart heating network energy conservation and emission reductionAutomatic fault reporting function: The monitoring point automatically reports the fault information to the monitoring center and prints the report information automatically. The automatic detection of faults includes: flowmeter communication failure, 220V AC power outage, IC card failure, etc., and the long-distance transmission distance can reach 1200 meters, which can reliably meet the needs of low-level data acquisition and transmission. At the same time, it also helps to reduce the distributed capacitance generated between two 485 communication lines and the surrounding communication lines. System maintenance includes communication settings, site settings, instrument settings, range settings, option settings, user management, permission settings, data initialization, password change, network settings, and other functions. The network settings are as follows: Users can make corresponding settings and changes according to their own company's actual situation
STR/WEB/V2.0Smart heating network energy conservation and emission reduction, thermal network recharge management, smart heating energy-saving applicationThe heating network center continuously collects various variable information (instantaneous flow rate, cumulative flow rate, pressure, temperature, compensation density, power status, valve status, power-off/power on time, prepaid steam balance, settlement balance, instrument key parameters, programming times, etc.) from various meters through a static IP transmission network, and saves these data in a universal database for generating various tables, curves, making report judgments, and reminding responsible personnel to process information through the Duanxin platform (SMS report). If required by the customer, the software provides a communication interface to provide data to the MIS system for operators to read and query the data. With the continuous development of urban construction and the expansion of supply areas such as hot water, steam, tap water, and gas, the traditional manual meter reading method can no longer meet the requirements of enterprises for cost recovery, instrument operation status, and the construction of digital management technology platforms. The basic function is to recharge first, then use gas, and automatically close the valve after use; Security: Three types of IC cards are used for management and operation, including equipment management card, user gas purchase card, and maintenance card; Cards and tables correspond one-to-one and cannot be used interchangeably. If the password verification fails three times in a row, the IC card will be locked and cannot be used for data writing operations. The report function automatically generates * *, monthly reports, and annual reports, and can also be used for statistical reporting and printing at any time. Automatic printing function can be set
At present, most heating companies supply steam first and then settle monthly when selling steam, but this may result in some user units defaulting on steam payments, causing inconvenience to heating companies. The steam IC card prepayment control system developed by Qingdao Hesheng Company can effectively eliminate the above-mentioned problems. The steam users of this system must pay in advance and recharge before opening the valve to use steam. They must also renew and recharge before the balance is exhausted. When the balance is insufficient, local and remote notifications will be sent to remind users to pay in a timely manner. If the balance is not renewed in time, the system will automatically close the valve and stop steam when the balance is zero, eliminating the phenomenon of overdue payment by the steam users. combineSmart heating network energy conservation and emission reductionReal time customer gas usage status, the system control box has unboxing and disconnection reports. Once a customer opens the metering box or system control box without authorization, the data will be immediately transmitted to the control center to remind the staff of the time, and the electric valve will be remotely controlled to close and stop the steam supply, which will have a deterrent effect on malicious behavior by users.
Smart heating network energy conservation and emission reduction, thermal network recharge management, smart heating energy-saving applicationMore and more attention is being paid to heating enterprises. By using remote monitoring to track the entire heating network pipeline and instruments, not only can the heating status of the entire heating network pipeline be grasped, but also the instrument fault report information can be quickly and accurately reflected, making it convenient for maintenance personnel to check and repair in a timely manner. This not only saves a lot of manpower and material resources, but also improves the modern management level of the heating network. If the remote network is complete, the meter reading personnel can also serve as personnel. If any problems are found in the room, they can go to check at any time to reduce the possibility of gas theft and create a deterrent effect on users, so that they do not want to steal gas, thereby reducing the losses of the gas supply enterprise.
Qingdao Hesheng Zhiyuan Automation System Co., Ltd
189 Hui Xin 5483 Same number 1481
Q:3438-5007-67
AfterSalesService :
Key words:- Smart heating network energy conservation and emission reduction
More Products