Intelligent heating information management, online monitoring of vortex flow meters, introduction to intelligent heating
Category:
Instrumentation/Flow meter/flowmeter
Model:
STR/WEB/V2.0
Brand:
Qingdao Zhiyuan Instrument
model:
STR/WEB/V2.0
principle:
ultrasonic flowmeter
purpose:
gas flow meter
Nominal Diameter:
DN15-2000
work pressure:
1.6MPa
Applicable Medium:
Gas, liquid, steam
Operating Temperature:
three hundred
measurement range:
eight thousand nine hundred and forty-eight
accuracy class:
one
measurement accuracy:
one
Installation type:
flange connection
flow range:
two thousand eight hundred and thirty-five
Processing & Customization:
yes
weight:
fifty-two
Place of Origin:
Qingdao, China
manufacturer:
Qingdao Zhiyuan Instrument
Retail Price
4,533.00USD
重量
kg
- Product Description
-
model STR/WEB/V2.0
principle ultrasonic flowmeter
purpose gas flow meter
Nominal Diameter DN15-2000
work pressure 1.6MPa
Applicable Medium Gas, liquid, steam
Operating Temperature three hundred
measurement range eight thousand nine hundred and forty-eight
accuracy class one
measurement accuracy one
Installation type flange connection
flow range two thousand eight hundred and thirty-five
Processing & Customization yes
weight fifty-two
Place of Origin Qingdao, China
manufacturer Qingdao Zhiyuan Instrument
Description :

Intelligent heating information management, online monitoring of vortex flow meters, introduction to intelligent heatingPrepaid function Prepaid function, divided into automatic mode and manual mode. Automatic mode: The valve with a remaining capacity is open, and the valve with a remaining capacity of 0 is closed; Manual mode: The valve opening can be adjusted with or without a margin, but when there is no margin, the valve can be manually opened, and the negative value of the margin will be automatically deducted after resetting.
Recharge requires 2 people to complete. After the personnel submit the recharge request and confirm its accuracy, they will review and approve it on their own. If there are any errors, the recharge will be rejected; If the personnel confirm that their recharge is correct and approved, then the recharge is successful; If the confirmation is incorrect, the recharge will be rejected. After successful recharge, the recharge information will be sent to the customer via duanxin.
For incorrect recharge, if the recharge has been successful, you can operate the red flush setting to clear the recharge. The recharge of -6 in the picture is the red flush setting.
Settlement reports can be generated based on custom time periods
Rate modification function to meet the demand for adjusting gas source prices in different periods;
Intelligent heating information management, online monitoring of vortex flow meters, introduction to intelligent heatingThe main advantage is its use in combined cooling, heating, and power generation. Co production conforms to the principle of "cascade utilization" of the total energy system and will achieve good energy utilization efficiency, with great development prospects. Although large (thermal) power plants can transmit electricity over long distances, they require the construction of power grids, substations, and distribution stations, and have transmission losses. Steam and hot water cannot be effectively transmitted over long distances like electricity. So unless specially designed and arranged in advance, it is difficult to achieve the purpose of transporting steam and hot water. Because the location of large power plants has its own requirements, generally speaking, it is difficult to have a sufficient number of suitable cold and heat energy users nearby, making it impossible to carry out effective co production. Distributed energy systems, on the other hand, are exactly the opposite. They can be set up nearby according to demand, and can cooperate with users as well as possible without the problem of long-distance transmission of cold and heat energy(Click to view more)
At present, most heating companies supply steam first and then settle monthly when selling steam, but this may result in some user units defaulting on steam payments, causing inconvenience to heating companies. The steam IC card prepayment control system developed by Qingdao Hesheng Company can effectively eliminate the above-mentioned problems. The steam users of this system must pay in advance and recharge before opening the valve to use steam. They must also renew and recharge before the balance is exhausted. When the balance is insufficient, local and remote notifications will be sent to remind users to pay in a timely manner. If the balance is not renewed in time, the system will automatically close the valve and stop steam when the balance is zero, eliminating the phenomenon of overdue payment by the steam users. combineSmart heating information managementReal time customer gas usage status, the system control box has unboxing and disconnection reports. Once a customer opens the metering box or system control box without authorization, the data will be immediately transmitted to the control center to remind the staff of the time, and the electric valve will be remotely controlled to close and stop the steam supply, which will have a deterrent effect on malicious behavior by users.
Intelligent heating information management, online monitoring of vortex flow meters, introduction to intelligent heatingThe mobile data transmission network is a critical part of the system, connecting the past and the future, directly determining the operational effectiveness of the entire system. This part is built and maintained by mobile operators, ensuring reliability and stability, and users do not need to invest any additional funds. The mobile data transmission system for prepaid flow meters in the heating network connects the station and the center through GPRS/LTE communication modules and the Internet (static IP network cable) as a medium. The intelligent thermal measurement system station packages various data and transmits it to the GPRS/LTE communication module through communication lines. The GPRS/LTE communication module encodes and processes the data, converts it into a format for public network data transmission, and sends it to the data network location of the mobile operator. The static IP extracts the data and finally transmits it to the central server.
Qingdao Hesheng Zhiyuan Automation System Co., Ltd
189 Hui Xin 5483 Same number 1481
Q:3438-5007-67
AfterSalesService :
Key words:- Smart heating information management
More Products