Smart heating operation management, heating station meter reading system, wireless data remote transmission terminal
Category:
Instrumentation/Flow meter/flowmeter
Model:
STR/WEB/V2.0
Brand:
Qingdao Zhiyuan Instrument
model:
STR/WEB/V2.0
principle:
Differential pressure flowmeter
purpose:
High flow flowmeter
Nominal Diameter:
DN15-2000
work pressure:
1.6MPa
Applicable Medium:
Gas, liquid, steam
Operating Temperature:
three hundred
measurement range:
nine thousand nine hundred and ninety-three
accuracy class:
one
measurement accuracy:
one
Installation type:
flange connection
flow range:
three thousand eight hundred and seventy-nine
Processing & Customization:
yes
weight:
seventeen
Place of Origin:
Qingdao, China
manufacturer:
Qingdao Zhiyuan Instrument
Retail Price
3,095.00USD
重量
kg
- Product Description
-
model STR/WEB/V2.0
principle Differential pressure flowmeter
purpose High flow flowmeter
Nominal Diameter DN15-2000
work pressure 1.6MPa
Applicable Medium Gas, liquid, steam
Operating Temperature three hundred
measurement range nine thousand nine hundred and ninety-three
accuracy class one
measurement accuracy one
Installation type flange connection
flow range three thousand eight hundred and seventy-nine
Processing & Customization yes
weight seventeen
Place of Origin Qingdao, China
manufacturer Qingdao Zhiyuan Instrument
Description :

Smart heating operation management, heating station meter reading system, wireless data remote transmission terminalPartial Function Introduction:The data analysis function includes steam analysis of the sum of total table and settlement flow, steam analysis of settlement flow of each sub table and branch line, represented in the form of curves and reports, and can automatically generate pipe losses for each pipeline;
The system software adopts a networked design, supporting multiple network interfaces and remote browsing. After running the program on the server side, the screen will be published, and various data can be shared by other departments of the thermal power plant through the IE browser. The system has communication function with the power plant MIS system and can transmit the heat network signal to the upper information management system;
The main function of the smart heating network supports large screen projection function, which can send geographic graphics, data, curves, pipeline diagrams, etc. displayed on the computer to the large screen, making the system have good visibility;
The design of system software and hardware can facilitate future expansion, upgrading, and transformation; The hardware adopts modular design, which is convenient for transformation and upgrading.
Equipped with operation logs, it can query the operation process and modify parameters of each customer, achieve traceable and orderly supervision, and avoid operational errors that cannot be traced
Smart heating operation and managementValve regulation function 2: Over flow limiting function, which automatically reduces the valve opening when the flow exceeds the set value. The small flow valve closing function automatically closes the valve when the flow rate remains below the set value for a period of time. Curve analysis: It can compare the pressure, temperature, and instantaneous flow values of each instrument at different time periods. Furthermore, obtain their fluctuation situation, clarify the reasons for their fluctuations, in order to formulate corresponding measures
Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart heating operation and managementGeneral function introduction:
System information management: database server parameter settings, communication server information settings, operator information management, password modification, industry category settings, system announcement information management. User Information Management: Regional Information Management, User Information Management, Measurement Point Information Management, and Meter Information Management. Flow monitoring management: New data monitoring of flow meters, supplementary recording of water meter data, monitoring of water meters: instantaneous flow, positive cumulative flow, negative cumulative flow. Inspection and repair management: flowmeter inspection management, water meter repair management. Data query management: user information query, measurement point information query, water and gas situation query, report information query, operation log query, historical data query. Statistical report generation: Generate reports by hour, day, week, ten day, month, year, and other time periods, and generate water usage details by year, month, and day. Usage analysis curve: Plot the water usage data of each station's flow meter into hourly, daily, ten day, monthly, annual and other time periods.
Smart heating operation management, heating station meter reading system, wireless data remote transmission terminalIt can also provide the user unit with greater regulation, control, and guarantee capabilities, ensuring that various secondary energy sources of the user unit can be fully supplied. It is very suitable for providing electricity, heating, and cooling to developing areas, commercial and residential areas, rural areas, pastoral areas, and mountainous areas, greatly reducing environmental pressure. In short, distributed energy systems can meet the needs of special occasions, provide possibilities for the comprehensive cascade utilization of energy, open up new directions for the utilization of renewable energy, and make outstanding contributions to improving energy utilization efficiency, enhancing safety, and addressing environmental pollution. This is also a very important advantage. The GPRS wireless data remote meter reading system for intelligent heating operation and management is designed and developed by our company to solve the above problems. It ensures the safe operation of the heating network system, facilitates the rational allocation of energy, is economically practical, and can timely detect problems, reduce losses. The phenomenon of "steam (water) confusion" has taken the management of the heating network to a higher level, achieving the goal of seeking benefits from management. After the system was established, the value reading time of the meter was unified, changing the original 15-30 minute manual reading time, achieving fairness in assessment while reducing the labor intensity of personnel, and reasonably allocating resources such as personnel, finance, and materials, improving efficiency and realizing the transformation of economic benefits
Qingdao Zhiyuan Instrument Prepaid Calculator complies with the JJG1003-2016 standard and meets the trade settlement requirements of the new metering regulations for integrated calculators.
A. Instrument model EF-II/TCP, LCD display screen.
B. The instrument has an accuracy of ± 0.2% and is capable of outputting 4-20mA analog signal current (output category can be freely defined).
C. The function of intelligent accumulation instrument is to measure pressure, temperature, instantaneous flow rate, cumulative flow rate, frequency, differential pressure, steam balance, power outage frequency, power outage and incoming call time, daily cumulative monthly cumulative query, etc. It is programmable and can set parameters according to actual needs;
D. Multiple cumulative methods (lower limit flow, over flow), cumulative coefficient (percentage) can be set. It can be set that when the flow rate is less than a certain percentage of the range (such as 10%), the lower limit flow rate will be accumulated according to this fixed value. It can also be set that when the flow rate is greater than a certain percentage of the range (such as 110%), the excess flow rate will be accumulated according to the set multiplier, thus solving the problem of low flow rate in small flow and excess flow measurement and meeting the actual needs of heat network calculation.
Qingdao Hesheng Zhiyuan Automation System Co., Ltd
189 Hui Xin 5483 Same number 1481
Q:3438-5007-67
AfterSalesService :
Key words:- Smart heating operation and management
More Products