Smart heating management system, superheated steam metering, wireless data remote transmission platform
Smart heating management system, superheated steam metering, wireless data remote transmission platform

Smart heating management system, superheated steam metering, wireless data remote transmission platform

Category:

Instrumentation/Flow meter/flowmeter

Model:

STR/WEB/V2.0

Brand:

Qingdao Zhiyuan Instrument

model:

STR/WEB/V2.0

principle:

Variable area flowmeter

purpose:

gas flow meter

Nominal Diameter:

DN15-2000

work pressure:

1.6MPa

Applicable Medium:

Gas, liquid, steam

Operating Temperature:

three hundred

measurement range:

three thousand one hundred and twenty-one

accuracy class:

one

measurement accuracy:

one

Installation type:

flange connection

flow range:

two hundred and eighty-eight

Processing & Customization:

yes

weight:

six

Place of Origin:

Qingdao, China

manufacturer:

Qingdao Zhiyuan Instrument

Retail Price

6,224.00USD


重量

kg

  • Product Description
  • model

    STR/WEB/V2.0

    principle

    Variable area flowmeter

    purpose

    gas flow meter

    Nominal Diameter

    DN15-2000

    work pressure

    1.6MPa

    Applicable Medium

    Gas, liquid, steam

    Operating Temperature

    three hundred

    measurement range

    three thousand one hundred and twenty-one

    accuracy class

    one

    measurement accuracy

    one

    Installation type

    flange connection

    flow range

    two hundred and eighty-eight

    Processing & Customization

    yes

    weight

    six

    Place of Origin

    Qingdao, China

    manufacturer

    Qingdao Zhiyuan Instrument

    Description :

    Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart heating management system, superheated steam metering, wireless data remote transmission platformSystem functions:

      a. Can query historical data of any hot user, any parameter, and any time period, and support the export and printing functions of statistical reports and analysis curves; Rich report customization printing and archiving functions, which can print hot user daily, monthly, and steam consumption detail reports, parent pipe daily, monthly, and summary reports, and can be archived as EXCEL format files (*. xls). b. Hot user management data system, including flow rate, pressure, temperature, upper and lower limit report settings, current operating parameters of instruments, unit price, special policies, responsible person information, etc., to prevent users from modifying settings; c. Access control function: Operators need to apply for a login name with their personal ID when logging in (non ID cannot be applied for), and achieve real name login; After entering the password and passing the identity verification, the system can enter the system. The system defines access permissions according to different access users. d. The comprehensive energy system of the industrial park adopts a B/S structure and supports intelligent terminals with internet access functions, enabling the operation of the heating network anytime, anywhere and achieving mobile office; e. Geographical distribution map of heating network users and routing map of heating network pipelines, which can be drawn according to the needs of the network and marked with steam flow direction (green line in the figure), locate the coordinate points of heating network users, and display the pipeline distance between heating customers and heat sources;

      f. If the smart heating management system has a gas flow meter on site, we do not need to use our flow integrator. Only the on-site flow meter needs to have RS485 communication function. Based on the communication protocol of the meter, we develop communication software and directly connect it to the IC card controller through RS485 line. The IC card gas sales management system consists of the following hardware: IP network cable, server, IC card reader/writer, etc. The main software includes operating system software, database software, heat network data IC card management system software, and firewall software. Its main functions are as follows: file management function (1) operator profile: establish login username and password, and grant corresponding operation permissions. (2) Terminal profile: Information parameters for registering a terminal. (3) Meter file: Register information for all meters

    STR/WEB/V2.0Smart heating management system, superheated steam metering, wireless data remote transmission platformThe heating network center continuously collects various variable information (instantaneous flow rate, cumulative flow rate, pressure, temperature, compensation density, power status, valve status, power-off/power on time, prepaid steam balance, settlement balance, instrument key parameters, programming times, etc.) from various meters through a static IP transmission network, and saves these data in a universal database for generating various tables, curves, making report judgments, and reminding responsible personnel to process information through the Duanxin platform (SMS report). If required by the customer, the software provides a communication interface to provide data to the MIS system for operators to read and query the data. The wireless remote intelligent meter reading system of the smart heating energy-saving system is built on the network of the GPRS data management center established within the enterprise. It transmits all incoming traffic data to the data center through a mobile GPRS network. Based on the actual situation of various meters being relatively centralized, the low-level network of the system adopts RS485 bus. It has the characteristics of simple structure, low cost, and low wiring requirements

      Distributed energy management system is relative to traditional centralized energy supply systems. Traditional centralized energy supply systems use large capacity equipment, centralized production, and then transmit various types of energy to numerous users over a large area through door transmission facilities (such as large power grids, large heat grids, etc.); Distributed energy systems, on the other hand, are small and medium-sized energy conversion and utilization systems that directly face users, produce and supply energy on-site according to their needs, have multiple functions, and can meet multiple objectives.Smart Heating Management SystemThe main functions implemented are as follows: file management function (1) operator file: establish login username and password, and grant corresponding operation permissions. (2) Terminal profile: Information parameters for registering a terminal. (3) Meter file: Register all meter information, data recovery function: In case of accidental damage to the control instrument, internal data (mainly user recharge balance) can be recovered, effectively avoiding the occurrence of both parties. Open database design: supports user-defined monitoring station expansion and monitoring sensor expansion. Adapt to the continuous development needs of enterprises

      Qingdao Hesheng Zhiyuan Automation System Co., LtdSmart Heating Management SystemIntelligent report 1. It can automatically generate daily reports, monthly reports, annual reports, and reports, and can print reports in real time. 2. It can query historical data reports for any hot user, any parameter, and any time period, and supports exporting statistical reports and analysis curves. 3. It can print daily, monthly, and detailed reports on gas consumption for each individual user and all users, as well as contemporaneous and annual reports, and can be archived as Excel files (*. xls). 4. The report format can be created according to the requirements of the bidding party, and the system needs to have monthly automatic settlement function to generate electricity meters. 5. The remote automatic meter reading system can perform real-time data calling and historical data query on the backend software. The storage period of historical data is long, and the communication function provides RS485 communication interface, which can be connected through wired, GPRS/CDMA and other methods, using the standard Modbus RTU protocol. In the late 1980s and early 1990s, pilot work on automated meter reading systems began. Various power supply enterprises across the country have basically established wireless power load control systems. Although their main construction purpose is to control loads, they are gradually being used for reading electricity meters for large users

      Qingdao Hesheng Zhiyuan Automation System Co., Ltd

      189 Hui Xin 5483 Same number 1481

      Q:3438-5007-67

    AfterSalesService :

    Key words:
    • Smart Heating Management System