Smart heating network system for power plants, data collection for external steam supply, and GPRS wireless meter reading design
Smart heating network system for power plants, data collection for external steam supply, and GPRS wireless meter reading design

Smart heating network system for power plants, data collection for external steam supply, and GPRS wireless meter reading design

Category:

Instrumentation/Flow meter/flowmeter

Model:

STR/WEB/V2.0

Brand:

Qingdao Zhiyuan Instrument

model:

STR/WEB/V2.0

principle:

Differential pressure flowmeter

purpose:

High flow flowmeter

Nominal Diameter:

DN15-2000

work pressure:

1.6MPa

Applicable Medium:

Gas, liquid, steam

Operating Temperature:

three hundred

measurement range:

eight thousand four hundred and seventy-five

accuracy class:

one

measurement accuracy:

one

Installation type:

flange connection

flow range:

five thousand six hundred and forty-two

Processing & Customization:

yes

weight:

sixty-one

Place of Origin:

Qingdao, China

manufacturer:

Qingdao Zhiyuan Instrument

Retail Price

4,858.00USD


重量

kg

  • Product Description
  • model

    STR/WEB/V2.0

    principle

    Differential pressure flowmeter

    purpose

    High flow flowmeter

    Nominal Diameter

    DN15-2000

    work pressure

    1.6MPa

    Applicable Medium

    Gas, liquid, steam

    Operating Temperature

    three hundred

    measurement range

    eight thousand four hundred and seventy-five

    accuracy class

    one

    measurement accuracy

    one

    Installation type

    flange connection

    flow range

    five thousand six hundred and forty-two

    Processing & Customization

    yes

    weight

    sixty-one

    Place of Origin

    Qingdao, China

    manufacturer

    Qingdao Zhiyuan Instrument

    Description :

    Qingdao Zhiyuan InstrumentSmart heating network system for power plantsFunction Introduction:

      1. Dynamic display of valve status, unboxing status, instantaneous flow rate, pressure, temperature, cumulative flow rate, etc. for each hot user, with different colors used to represent different statuses; When each user point is in normal state, it is displayed in blue. When the parameters exceed the limit, it is reported, or there is a fault, it is displayed in red and flashes, and information is synchronously sent to notify personnel; 2. Real time historical data and curves of flow rate, pressure, temperature, density, differential pressure, and frequency are displayed in the same coordinate system, and can be freely compared. The mouse follows and displays the current data, which is intuitive and easy to analyze; 3. The centralized water supply management platform can directly add hot customers through the front-end webpage, with convenient and fast operation, sorted by number, and the order of customer arrangement can be freely adjusted; Provide detailed information on thermal units, establish maintenance information for measuring equipment, and facilitate management personnel to query the history and current status of instruments; 4. Automatically generate daily, monthly, annual, and report forms, and be able to print reports in real time. Reports can be made according to the requirements of the thermal company. 5. Thermal user management data system, including flow rate, pressure, temperature, upper and lower limit report settings, instrument current operating parameters, unit price, special policies, responsible person information, etc., to prevent users from modifying settings; 6. Multi level operation permissions for the steam meter reading system are set and controlled by administrators to prevent unauthorized operations by personnel at different levels;

    Qingdao Hesheng Zhiyuan Automation System Co., Ltd. Power Plant Smart Heating Network SystemMeasurement software follows standards:

      Specification for Computer Software Quality Assurance Plan GB/T12505

      General Technical Specifications for Microcontrollers GB/T9813-2000

      GB 4728.1-85 "Symbols for Electrical Diagrams"

      Standard for Intelligent Flow Display Instrument JJG1003-2016

      Vortex Flow Meter JB/T9249-2015

      Verification Regulations for Vortex Flowmeters JJG1029-2007

      Verification Regulations for Differential Pressure Flowmeters JJG640-2016

      Differential Pressure Flow Meter GB/T2624-2006

      Qingdao Hesheng CompanySmart heating network system for power plants, data collection for external steam supply, and GPRS wireless meter reading designAdvantage:

      1. On site operation data 4G real-time upload: 4G wireless communication terminals are responsible for the important task of data transmission, and can upload on-site data to the heating network service center in real time to track and monitor the thermal parameters (pressure, temperature, flow rate, etc.) of the heating network, and grasp the heating status of the entire heating network management line. 2. Flexible networking and rapid deployment: Wireless networking mode has the characteristics of flexible networking, high data transmission rate, wide signal coverage, strong real-time performance, high security, low operating cost, and low maintenance cost; Suitable for situations where equipment is widely distributed and it is inconvenient to install network cables, wireless networking can achieve data transmission without geographical limitations as long as the operator's network coverage is available, shortening the project deployment cycle. 3. Fault diagnosis and analysis, timely fault reminder: on-site collection and measurement instrument failures can also be detected in a short period of time, and the fault time can be recorded and filed to avoid measurement losses and eliminate the idea of users stealing steam. In case of power outages or abnormal collection parameters at the hot user end, information can be timely predicted and personnel can be reminded to handle them through platforms or methods. 4. Remote operation and maintenance management, reducing operation and maintenance costs: Management personnel can see the steam usage of users in various places in the management background, without the need for on-site manual meter reading. Fault report information is convenient for maintenance personnel to check and repair in a timely manner, reducing and saving a lot of manpower and material resources

      5. Remote meter reading system terminal active calling function: It can actively extract data from monitoring points on the server of the dispatch center at any time. The system integrates the automatic collection and settlement of energy data such as water, steam, and heat, remote prepayment, and intelligent charging functions into a unified intelligent remote prepayment system. The open database design supports user-defined expansion of monitoring stations and monitoring sensors. To meet the needs of the continuous development of enterprises, the GPRS meter reading system is connected to the Internet network and communicates with the main station computer through the GPRS network. The user's data is processed and protocol encapsulated by the GPRS module before being sent out. It is then received by the GPRS receiving module and transmitted to the main station via the Internet network, achieving real-time online connection between the user's energy consumption data and the main station

    Smart heating network system for power plants, data collection for external steam supply, and GPRS wireless meter reading designMore and more attention is being paid to heating enterprises. By using remote monitoring to track the entire heating network pipeline and instruments, not only can the heating status of the entire heating network pipeline be grasped, but also the instrument fault report information can be quickly and accurately reflected, making it convenient for maintenance personnel to check and repair in a timely manner. This not only saves a lot of manpower and material resources, but also improves the modern management level of the heating network. If the remote network is complete, the meter reading personnel can also serve as personnel. If any problems are found in the room, they can go to check at any time to reduce the possibility of gas theft and create a deterrent effect on users, so that they do not want to steal gas, thereby reducing the losses of the gas supply enterprise.

      Qingdao Hesheng Zhiyuan Automation System Co., Ltd

      189 Hui Xin 5483 Same number 1481

      Q:3438-5007-67

    AfterSalesService :

    Key words:
    • Smart heating network system for power plants