Steam metering management terminal, GPRS data collection, cloud platform meter reading system software
Steam metering management terminal, GPRS data collection, cloud platform meter reading system software

Steam metering management terminal, GPRS data collection, cloud platform meter reading system software

Category:

Instrumentation/Flow meter/flowmeter

Model:

STR/WEB/V2.0

Brand:

Qingdao Zhiyuan Instrument

model:

STR/WEB/V2.0

principle:

Fluid oscillating flowmeter

purpose:

steam flow meter

Nominal Diameter:

DN15-2000

work pressure:

1.6MPa

Applicable Medium:

Gas, liquid, steam

Operating Temperature:

three hundred

measurement range:

seven thousand nine hundred and twenty-six

accuracy class:

one

measurement accuracy:

one

Installation type:

flange connection

flow range:

five thousand and ninety-three

Processing & Customization:

yes

weight:

twenty-seven

Place of Origin:

Qingdao, China

manufacturer:

Qingdao Zhiyuan Instrument

Retail Price

4,309.00USD


重量

kg

  • Product Description
  • model

    STR/WEB/V2.0

    principle

    Fluid oscillating flowmeter

    purpose

    steam flow meter

    Nominal Diameter

    DN15-2000

    work pressure

    1.6MPa

    Applicable Medium

    Gas, liquid, steam

    Operating Temperature

    three hundred

    measurement range

    seven thousand nine hundred and twenty-six

    accuracy class

    one

    measurement accuracy

    one

    Installation type

    flange connection

    flow range

    five thousand and ninety-three

    Processing & Customization

    yes

    weight

    twenty-seven

    Place of Origin

    Qingdao, China

    manufacturer

    Qingdao Zhiyuan Instrument

    Description :

    Qingdao Zhiyuan InstrumentSteam metering management terminalMain functions: 1. Anti theft function, 2. Prepaid function, 3. Remote meter reading function, 4. Anti strong magnetic, 5. Anti lightning function, 6. Generate various reports, 7. Arrears, reminders, and report information prompt function, 8. Steam metering management terminal, GPRS data collection, cloud platform meter reading system software IC card prepaid flowmeter also has RS485 communication, realizing data remote transmission, valve adjustment function, query and statistics: It can query and display data of each instrument at any time period of a certain period, making it easy to assess and query each shift. Traditional meter reading methods are easily affected by factors such as weather conditions and errors or omissions. However, the intelligent meter reading system directly eliminates the unstable link of manual operation, so with the help of this system, the cost of hot water and steam meters can be calculated

      Qingdao Zhiyuan InstrumentSteam metering management terminalFunction Introduction:

      1. Dynamic display of valve status, unboxing status, instantaneous flow rate, pressure, temperature, cumulative flow rate, etc. for each hot user, with different colors used to represent different statuses; When each user point is in normal state, it is displayed in blue. When the parameters exceed the limit, it is reported, or there is a fault, it is displayed in red and flashes, and information is synchronously sent to notify personnel; 2. Real time historical data and curves of flow rate, pressure, temperature, density, differential pressure, and frequency are displayed in the same coordinate system, and can be freely compared. The mouse follows and displays the current data, which is intuitive and easy to analyze; 3. The air prepaid system can directly add hot customers through the front-end webpage, with convenient and fast operation, sorted by number, and the order of customer arrangement can be freely adjusted; Provide detailed information on thermal units, establish maintenance information for measuring equipment, and facilitate management personnel to query the history and current status of instruments; 4. Automatically generate daily, monthly, annual, and report forms, and be able to print reports in real time. Reports can be made according to the requirements of the thermal company. 5. Thermal user management data system, including flow rate, pressure, temperature, upper and lower limit report settings, instrument current operating parameters, unit price, special policies, responsible person information, etc., to prevent users from modifying settings; 6. Multi level operation permissions for remote meter reading system terminals are set and controlled by administrators to prevent unauthorized operations by personnel at different levels;

      Qingdao Hesheng Smart Heating Network Heating User Management: 1. Basic information management of heating users, including user name, number, person, method, pipe diameter and wall thickness, metering equipment form (vortex street, orifice plate, etc.), declared steam consumption, commonly used steam consumption, etc. 2. Analyze the proportion of key users in branch lines, main lines, and overall thermal users, and provide scheduling optimization suggestions based on historical data and other factors to assess the impact of key user start stop on corresponding pipeline parameters. 3. Analysis report on peak and valley flow of hot users, statistics on load situation, and analysis to assist in formulating business plans. 4. Comparative analysis of temperature, pressure, and flow curves of thermal users with similar pipelines and diameters to assist in identifying pipeline anomalies.

      fiveSteam metering management terminalManagement center software functions: query and display of remaining gas volume of gas units, and reporting of insufficient remaining gas volume. Real time monitoring and display of user data maps (flow rate, pilot valve status, etc.), remote data demonstration function. In addition to the main dispatch center, the system can establish sub centers at any location where it wants to build sub centers. It is connected to the main center through GPRS network, which greatly facilitates user management and use. The development of technology has led to the increasing application of automation in work. With the continuous development of enterprises and the increasing number of various meters, traditional manual meter reading can no longer meet the requirements of modern enterprises, and is gradually being replaced by RS485 wired data remote meter reading systems

      Overall, a distributed energy system with renewable energy as the mainstay and flexible diversification is a vigorously developing energy optimization supply model in this century. Various new distributed energy systems are constantly being introduced, and with the advancement of science and technology and the development of high-performance new materials, distributed energy will occupy an increasingly large proportion in the social energy structure, which will have a crucial impact on social development. The economy has entered a period of rapid development, with increasing energy demand and supply bottlenecks becoming a long-term problem. Cities must learn to manage their own energy, as this is a key link in ensuring urban development and a basic requirement for the quality of urban managers.Steam metering management terminal, GPRS data collection, cloud platform meter reading system softwareGPRS wireless network provides a simple and effective means of communication and transmission for heating systems. The GPRS system can provide wide area wireless IP connectivity. The wireless data transmission of on-site instrument data has the advantages of fully utilizing existing networks, shortening construction cycles, and reducing construction costs. It is also easy to install and maintain equipment. Data management functions include data browsing, which allows browsing historical data separately and deleting, querying, and printing these data. For example, it can browse information stored in the database such as meter readings, statistical data, curve data, event data, etc., and export these data to generate corresponding reports for printing. System maintenance includes communication settings, site settings, instrument settings, range settings, option settings, user management, permission settings, data initialization, password changes, network settings, and other functions. The network settings are as follows: Users can make corresponding settings and changes according to their own company's actual situation, report or upload abnormal situations: The system will prompt and report the following four situations. According to user settings, when the balance of the gas fee is less than the set reporting value (on-site sound and light)

      Qingdao Hesheng Zhiyuan Automation System Co., Ltd

      189 Hui Xin 5483 Same number 1481

      Q:3438-5007-67

    AfterSalesService :

    Key words:
    • Steam metering management terminal