The role of smart heating platform, IC card data collection, and cloud platform meter reading system specification
Category:
Instrumentation/Flow meter/flowmeter
Model:
STR/WEB/V2.0
Brand:
Qingdao Zhiyuan Instrument
model:
STR/WEB/V2.0
principle:
ultrasonic flowmeter
purpose:
steam flow meter
Nominal Diameter:
DN15-2000
work pressure:
1.6MPa
Applicable Medium:
Gas, liquid, steam
Operating Temperature:
three hundred
measurement range:
five thousand two hundred and seventy-nine
accuracy class:
one
measurement accuracy:
one
Installation type:
flange connection
flow range:
two thousand four hundred and forty-six
Processing & Customization:
yes
weight:
fifty-nine
Place of Origin:
Qingdao, China
manufacturer:
Qingdao Zhiyuan Instrument
Retail Price
1,662.00USD
重量
kg
- Product Description
-
model STR/WEB/V2.0
principle ultrasonic flowmeter
purpose steam flow meter
Nominal Diameter DN15-2000
work pressure 1.6MPa
Applicable Medium Gas, liquid, steam
Operating Temperature three hundred
measurement range five thousand two hundred and seventy-nine
accuracy class one
measurement accuracy one
Installation type flange connection
flow range two thousand four hundred and forty-six
Processing & Customization yes
weight fifty-nine
Place of Origin Qingdao, China
manufacturer Qingdao Zhiyuan Instrument
Description :


STR/WEB/V2.0The role of smart heating platform, IC card data collection, and cloud platform meter reading system specificationThe heating network center continuously collects various variable information (instantaneous flow rate, cumulative flow rate, pressure, temperature, compensation density, power status, valve status, power-off/power on time, prepaid steam balance, settlement balance, instrument key parameters, programming times, etc.) from various meters through a static IP transmission network, and saves these data in a universal database for generating various tables, curves, making report judgments, and reminding responsible personnel to process information through the Duanxin platform (SMS report). If required by the customer, the software provides a communication interface to provide data to the MIS system for operators to read and query the data. The backup power supply of the steam prepayment control system is flexible: an external battery is used, and different battery capacities can be selected according to actual needs. When the external power supply (AC220V) is interrupted, it can maintain the continuous operation of the system's instruments (flow integrator, prepayment instrument), GPRS or CDMA modules. GPRS wireless network provides a simple and effective communication transmission method for the heating system. The GPRS system can provide wide area wireless IP connectivity. The wireless data transmission of on-site instrument data has the advantages of fully utilizing existing networks, shortening construction periods, and reducing construction costs. Additionally, the equipment is easy to install and maintain
Application of Qingdao STR/WEB/V2.0 Qingdao Zhiyuan Instrument Intelligent Heating System: The role of smart heating platformThe main application is to achieve intelligence and ensure thermal balance of heat source output. Install temperature, pressure, flow and other sensors at each heat source unit and pipeline outlet to calculate the energy consumption of each link, display information on inlet and outlet temperature, pressure, flow and other aspects. The sensors will send the collected information to the heating dispatch center to achieve real-time monitoring of various parameter information.The role of smart heating platform, IC card data collection, and cloud platform meter reading system specificationIn the application of heat source, it is also necessary to monitor load and weather changes, combine specific weather and load conditions, adhere to the principle of economic operation, compare the required heat with the heating amount, draw the trend curve of changes, and judge whether to start or stop the furnace. This will meet the heat needs of users without energy waste and save heating costs.
The role of smart heating platform, IC card data collection, and cloud platform meter reading system specificationPartial Function Introduction:
The data analysis function includes steam analysis of the sum of total table and settlement flow, steam analysis of settlement flow of each sub table and branch line, represented in the form of curves and reports, and can automatically generate pipe losses for each pipeline;
The system software adopts a networked design, supporting multiple network interfaces and remote browsing. After running the program on the server side, the screen will be published, and various data can be shared by other departments of the thermal power plant through the IE browser. The system has communication function with the power plant MIS system and can transmit the heat network signal to the upper information management system;
Boiler steam prepayment management supports large screen projection function, which can send geographic graphics, data, curves, pipeline diagrams, etc. displayed on the computer to the large screen, making the system have good visibility;
The design of system software and hardware can facilitate future expansion, upgrading, and transformation; The hardware adopts modular design, which is convenient for transformation and upgrading.
Equipped with operation logs, it can query the operation process and modify parameters of each customer, achieve traceable and orderly supervision, and avoid operational errors that cannot be traced
The role of smart heating platformLightning protection function: The box machine is equipped with a lightning protection module, but the control box must be reliably grounded. After the prepaid box is opened, a prompt will be displayed on the upper computer. After the interruption of the mains power (ac220v), the upper computer prompts
The role of smart heating platformOn site instrument installation:
The role of smart heating platform, IC card data collection, and cloud platform meter reading system specificationInstalling a protective box on the primary measuring equipment of the pipeline can provide shelter from wind and rain, protect the equipment, and extend its service life; 2、 It can prevent unauthorized operation of measuring equipment. The role of the smart heating platform is not limited to any type of flow meter. Choosing a flow meter that is suitable for the thermal user's operating conditions is the rigorous method. For steam metering schemes, the mainstream schemes are divided into two types: vortex street type and differential pressure type. In the actual heating process, we will cooperate with your side to conduct on-site inspections to determine which flow meter is more suitable for use.
Qingdao Hesheng Zhiyuan Automation System Co., Ltd
189 Hui Xin 5483 Same number 1481
Q:3438-5007-67
AfterSalesService :
Key words:- The role of smart heating platform
More Products