Siemens S120 single motor module 6SL3320-1TE36-1AA3 315kW industrial drive

Siemens S120 single motor module 6SL3320-1TE36-1AA3 315kW industrial drive

Category:

Electrical Engineering/source/Module power supply

Model:

6SL3320-1TE36-1AA3

Brand:

Siemens

Rated output current:

600 A

Adapt motor power:

315 kW

Input voltage range:

380-480 V AC

frequency range:

47-63 Hz

cooling method:

air cooling

Protection rating:

IP00

Control method:

Vector control/servo control

communication interface:

DRIVE-CLiQ

Installation Method:

Cabinet style installation

meet the standard:

IEC 61800-5-1

Retail Price

10,000,000.00USD


重量

kg

  • Product Description
  • Rated output current

    600 A

    Adapt motor power

    315 kW

    Input voltage range

    380-480 V AC

    frequency range

    47-63 Hz

    cooling method

    air cooling

    Protection rating

    IP00

    Control method

    Vector control/servo control

    communication interface

    DRIVE-CLiQ

    Installation Method

    Cabinet style installation

    meet the standard

    IEC 61800-5-1

    Description :

      6SL3320-1TE36-1AA3 is a high-performance single motor module from Siemens SINAMICS S120 series, designed specifically to solve high-precision motion control problems in heavy industrial equipment. This module is suitable for typical working conditions that require high dynamic response and precise torque control, such as large fans, pumps, compressors, and complex production line transmission systems. As the core power component of the S120 drive system, it can convert the DC bus voltage into a controlled three-phase AC voltage, directly driving asynchronous or synchronous servo motors. Its design aims to meet the continuous operation requirements in harsh industrial environments, ensuring stable speed and position control even in severe load fluctuations. It is the key hardware foundation for modern automated production lines to achieve high efficiency, energy saving, and precise operations.


      The rated output current of this single motor module is 600A, and the corresponding motor power is usually 315kW (depending on the specific grid voltage and overload factor, commonly used in 400V-480V three-phase AC systems). The product adopts a standard modular structure design and supports installation in either Booksize or Cabinet style, depending on the heat dissipation configuration and power level. The execution standard complies with IEC 61800-5-1 and UL certification requirements, and has CE mark. Internally integrated advanced IGBT power semiconductor devices, combined with optimized pulse width modulation (PWM) technology, effectively reduce switching losses and electromagnetic interference. The working temperature range is usually between 0 and 40 degrees Celsius, and the relative humidity needs to be controlled below 95% without condensation. The protection level is generally IP00, and it needs to be installed in a closed electrical cabinet that meets electrical specifications to ensure safe operation.


      When selecting, it is necessary to clearly distinguish the application scenarios of single motor modules from dual motor modules or multi axis modules. 6SL3320-1TE36-1A3 is designed to drive a single high-power motor. If multi axis synchronous control is required and the power is small, a multi axis module solution should be considered. Compared with traditional frequency converters, the S120 series single motor module supports vector control and servo control modes, with better dynamic performance, suitable for occasions with strict requirements for acceleration and deceleration time. Not applicable scenarios include independent operation requirements driven by non motor loads or without corresponding control units (CUs). The purchaser needs to pay attention to matching the corresponding incoming reactors, filters, and braking resistors to optimize power quality and handle regenerative energy, avoiding shutdowns caused by harmonic pollution of the power grid or overvoltage.


      When installing the 6SL3320-1TE36-1AA3 single motor module, sufficient upper and lower heat dissipation space must be ensured, and wiring operations must be carried out in accordance with hot swappable specifications. It is strictly prohibited to plug and unplug power cables and control plugs with power on. The typical usage cycle can reach more than 10 years, but it is necessary to regularly clean the dust in the air duct and check whether the fastening terminals are loose. Daily maintenance recommendations include monitoring module temperature, current load rate, and fault history through STARTER or TIA Portal software. Common faults include overcurrent, overheating, and DC bus undervoltage. When an alarm occurs, the insulation condition of the motor, whether the load is stuck, and whether the cooling fan is running normally should be checked first. Proper grounding and shielding treatment are crucial for reducing interference and extending the service life of single motor modules. It is essential to strictly follow the official wiring manual.

    AfterSalesService :

    Key words: