Intelligent VOC temperature and humidity monitoring explosion-proof cabinet, specialized safe storage cabinet for flammable and toxic substances
Category:
Electrical Engineering/Explosion proof electrical appliances/Explosion proof control box
Model:
explosion-proof cabinet
Brand:
Intelligent corrosion-resistant, fireproof and exp
material:
1.0-1.2mm cold-rolled steel plate
coating process:
Epoxy resin powder electrostatic spraying
monitoring parameters:
VOC concentration/temperature/humidity
alarm method:
Sound and light alarm+screen display
Fireproof structure:
Double wall filling with 38mm fireproof material
Leak proof design:
Bottom 5cm deep leakage trough
Lock type:
Three point linkage explosion-proof lock
Applicable Medium:
Flammable liquids/toxic substances/corrosive substances
certification standard:
CE/OSHA reference standards
Power supply requirements:
AC 220V/50Hz
Retail Price
10,000,000.00USD
重量
kg
- Product Description
-
material 1.0-1.2mm cold-rolled steel plate
coating process Epoxy resin powder electrostatic spraying
monitoring parameters VOC concentration/temperature/humidity
alarm method Sound and light alarm+screen display
Fireproof structure Double wall filling with 38mm fireproof material
Leak proof design Bottom 5cm deep leakage trough
Lock type Three point linkage explosion-proof lock
Applicable Medium Flammable liquids/toxic substances/corrosive substances
certification standard CE/OSHA reference standards
Power supply requirements AC 220V/50Hz
Description :
The intelligent VOC system explosion-proof cabinet is an industrial grade chemical storage device that integrates fire prevention, explosion prevention, leak prevention, and real-time environmental monitoring. It mainly solves the safety hazards caused by the accumulation of flammable liquids, toxic substances, and volatile organic compounds (VOCs) during storage in laboratories, factory workshops, and hazardous chemical warehouses. This explosion-proof cabinet uses a built-in high-precision sensor network to continuously monitor the temperature, humidity, and VOC concentration inside the cabinet 24/7. Once the data is abnormal, it will immediately sound and light an alarm and be linked to the exhaust system, effectively preventing fire, explosion, and personnel poisoning accidents. It is an intelligent safety protection terminal that meets modern EHS management requirements.

The main body of the explosion-proof cabinet is made of high-quality cold-rolled steel plate with a thickness of 1.0mm-1.2mm, which has been treated with acid pickling, phosphating, and epoxy resin powder electrostatic spraying, and has excellent acid and alkali corrosion resistance and mechanical strength. The cabinet structure follows a double wall design, with 38mm thick fire-resistant insulation material filled in the middle to ensure that the fire resistance limit meets the specified standards. The door panel is equipped with a three-point linkage lock and an anti leakage threshold groove. The bottom is equipped with a 5cm deep leakage groove, which can accommodate liquids that may accidentally leak. In terms of electrical systems, the top is integrated with an LCD display screen and control panel, and industrial grade temperature and humidity sensors and PID photoionization VOC detection probes are deployed internally. All electrical components are packaged in explosion-proof packaging, comply with GB 15603 and OSHA related safety standards, and have CE certification qualifications to ensure intrinsic safety in flammable and explosive environments.

When selecting, color codes should be distinguished based on the nature of the stored chemicals: yellow cabinets are dedicated to storing flammable liquids (such as acetone and ethanol), blue cabinets are used to store weakly corrosive or toxic substances, and red cabinets are usually used for flammable materials. This intelligent explosion-proof cabinet is particularly suitable for scenarios that are sensitive to air quality and require strict control of volatile substances, such as fine chemical research and development laboratories and pharmaceutical synthesis laboratories. If only basic physical isolation is required without environmental monitoring requirements, ordinary mechanical explosion-proof cabinets can be chosen to reduce costs; But if it involves highly toxic, volatile, or flammable chemicals, this intelligent model with VOC monitoring function must be selected. Please note that the cabinet size should match the on-site space and reserve a power interface to support the operation of intelligent modules.

When installing the intelligent VOC system explosion-proof cabinet, it must be placed on a well ventilated, flat ground away from heat and fire sources, and ensure that there is sufficient heat dissipation space on the back and side walls. After connecting the power, it is necessary to set the VOC concentration threshold (such as 10ppm) and temperature and humidity upper limits on the control panel, and regularly calibrate the sensor with standard gas to ensure detection accuracy. Daily maintenance includes checking the flexibility of the door lock, cleaning the accumulated fluid and debris in the leakage groove, and verifying whether the sound and light alarm functions properly. Common faults are often sensor drift or exhaust fan blockage. It is recommended to conduct a comprehensive electrical safety inspection and filter cleaning every six months. It is strictly prohibited to stack non chemical debris or privately connect non explosion proof electrical appliances in the cabinet to maintain its long-term stable protective effectiveness.
AfterSalesService :
质保两年Key words: