XGN15-12 High Voltage Incoming Cabinet 10kV Ring Network Switchgear Yunnan Patriotic Electric

XGN15-12 High Voltage Incoming Cabinet 10kV Ring Network Switchgear Yunnan Patriotic Electric

Category:

Electrical Engineering/High voltage electrical appliances/High voltage switchgear

Model:

XGN15/12

Brand:

Patriotic Electric

Rated voltage:

12kV

rated frequency:

50Hz

Rated Current:

630A/1250A

Rated short-time withstand current:

20kA/25kA

Protection rating:

IP4X

Overall dimensions:

1400×800×2300mm

Insulation medium:

SF6/Air

Execution Standard:

GB3906/IEC298

Retail Price

10,000,000.00USD


重量

kg

  • Product Description
  • Rated voltage

    12kV

    rated frequency

    50Hz

    Rated Current

    630A/1250A

    Rated short-time withstand current

    20kA/25kA

    Protection rating

    IP4X

    Overall dimensions

    1400×800×2300mm

    Insulation medium

    SF6/Air

    Execution Standard

    GB3906/IEC298

    Description :

      XGN15-12 high-voltage incoming cabinet is a fixed metal enclosed switchgear used in 10kV three-phase AC 50Hz power systems, mainly for receiving and distributing electrical energy. This device solves the problems of large volume and complex operation of traditional switchgear, and is particularly suitable for distribution systems in urban power grid renovation, residential areas, industrial and mining enterprises, and high-rise buildings. As a core component of the ring network power supply unit, XGN15-12 high-voltage incoming cabinet can ensure the safe and stable operation of the power system, meet the high standard requirements of users for power supply reliability, and typical working conditions include substation outgoing terminals and user receiving terminals.


      The XGN15-12 high-voltage incoming cabinet is designed and manufactured in accordance with national and international standards such as GB3906 and IEC298. The rated voltage is 12kV, the rated current is usually 630A or 1250A, and the rated short-time withstand current can reach 20kA or 25kA (4s). The cabinet is made of high-quality steel plates bent and welded, and the surface is treated with electrostatic spraying, which has good anti-corrosion performance and mechanical strength. The internal component layout is reasonable, and the busbar room, circuit breaker room, and cable room are isolated from each other, effectively preventing misoperation and the spread of arc faults. The insulation medium usually uses SF6 gas or air insulation, depending on the type of load switch configuration, to ensure excellent insulation performance even in harsh environments.


      When selecting the XGN15-12 high-voltage incoming cabinet, it is necessary to clarify the system voltage level, rated current size, and short-circuit breaking capacity requirements. This cabinet type is suitable for situations that require frequent operation and strict space occupancy restrictions. Compared with mid mounted handcart cabinets such as KYN28, the XGN15 series has a more compact structure and lower cost, but its maintenance flexibility is slightly inferior to handcart cabinets. If the system requires extremely high continuous power supply capability and rapid maintenance and replacement, it is necessary to evaluate whether to combine bypass schemes or choose other cabinet types. In addition, it is necessary to confirm whether automated interfaces are required to achieve remote monitoring and protection functions, ensuring compatibility with higher-level scheduling systems.


      When installing the XGN15-12 high-voltage incoming cabinet, it should be ensured that the foundation levelness meets the specifications, the grounding resistance is less than 4 ohms, and the direction of cable entry and exit needs to be determined according to the actual layout on site. It is recommended to regularly check the SF6 gas pressure (if applicable), contact condition of contacts, and lubrication status of mechanical transmission components for daily maintenance. A preventive test should be conducted every six months, including circuit resistance testing and insulation resistance measurement. Common faults include mechanism jamming, indicator malfunction, etc., which can be detected in advance through observation window status indication and partial discharge detection. During long-term operation, attention should be paid to keeping the cabinet dry and clean, preventing condensation from causing insulation degradation, and ensuring that the high-voltage incoming cabinet is always in the best working condition.

    AfterSalesService :

    Key words: