Dual power distribution box SDY series automatic switching emergency power supply Yunnan Patriotic Electric
Category:
Electrical Engineering/Distribution and transmission equipment/Distribution box
Model:
SDY
Brand:
Yunnan Patriotic Electric
Rated working voltage:
AC 380V/220V
rated frequency:
50Hz
Rated Current:
63A-630A
switch time:
≤1-3s
Protection rating:
IP30-IP54
Installation Method:
Wall mounted/floor standing
Shell material:
Cold rolled steel plate/stainless steel
Execution Standard:
GB/T 14048.11
Retail Price
10,000,000.00USD
重量
kg
- Product Description
-
Rated working voltage AC 380V/220V
rated frequency 50Hz
Rated Current 63A-630A
switch time ≤1-3s
Protection rating IP30-IP54
Installation Method Wall mounted/floor standing
Shell material Cold rolled steel plate/stainless steel
Execution Standard GB/T 14048.11
Description :
The dual power distribution box (SDY) is a distribution equipment used to achieve automatic or manual switching between two independent power sources, mainly solving the problem of uninterrupted power supply for important loads in the event of a power failure in one power source. This device is widely used in typical working conditions such as hospitals, data centers, high-rise buildings, and industrial production that require extremely high power supply continuity. By monitoring the status of the main and backup power sources in real-time, the dual power distribution box SDY can quickly switch the load to the backup power source when the main power source experiences undervoltage, overvoltage, phase loss, or power outage, ensuring the normal operation of key equipment and avoiding economic losses or safety accidents caused by power outages. It is the core component of ensuring power supply reliability in low-voltage distribution systems.
The dual power distribution box SDY is usually made of cold-rolled steel plate or stainless steel material box, with a surface treated with electrostatic spraying, which has good anti-corrosion and anti rust performance. The protection level generally reaches IP30 to IP54 standards, adapting to different indoor environmental requirements. The internal core components include high-performance dual power automatic transfer switches (ATS), circuit breakers, indicator lights, and control modules, which comply with national standards such as GB/T 14048.11. The electrical clearance and creepage distance strictly follow the specifications, and the rated insulation voltage is usually 690V or higher, which can withstand a certain short-term withstand current impact. The design of the box structure is reasonable, and the incoming and outgoing lines are flexible. It supports upper and upper or lower entry and lower exit, making it convenient for on-site wiring and maintenance, ensuring the safety and stability of electrical connections.
When selecting a dual power distribution box SDY, it is necessary to clarify the load nature, rated current size, and switching time requirements. Suitable for primary or secondary load scenarios such as fire pumps, elevators, lighting systems, and precision instruments. If the load contains a large amount of inductive or capacitive components, it is necessary to confirm whether the on and off capabilities of the switch match. Compared with a single power distribution box, the dual power distribution box SDY adds backup circuits and control logic, with slightly higher cost but significantly improved safety. Not suitable for non essential loads or general civilian occasions that are not sensitive to power outages, it is more economical to choose a regular distribution box in this case. When purchasing, it is necessary to verify whether the voltage level and frequency of the main and backup power supplies are consistent, and whether they have dual protection functions of mechanical interlocking and electrical interlocking.
When installing the dual power distribution box SDY, it should be vertically fixed to the wall or installed on the ground to ensure a solid foundation and sufficient space for heat dissipation and operation should be reserved around it. When wiring, it is necessary to strictly distinguish the phase sequence of the main power supply and the backup power supply to avoid equipment damage caused by reverse connection. It is recommended to regularly check the sealing of the box, the contact condition of the contacts, and the status of the indicator lights for daily maintenance, and clean the accumulated dust to prevent short circuits. Common faults include switching failures or abnormal indications, often caused by power outages or mechanical blockages in the control circuit. It is necessary to promptly investigate the control circuit fuses and linkage mechanisms. It is recommended to conduct regular manual or electric switching tests on switches that have not been activated for a long time to verify the reliability of the dual power distribution box SDY and extend the service life of the equipment.