Orbon AC/DC asynchronous motor Alpa power efficient and energy-saving industrial drive motor
Category:
hardware/Electric motor/asynchronous motor
Model:
customization supported
Brand:
Oubang
rated power:
0.75-315 kW
rated voltage:
220V/380V/DC 110-440V
insulation class:
F-level/H-level
Protection level:
IP54/IP55
working system:
S1 continuous working system
cooling method:
IC411 self fan cooling
Retail Price
10,000,000.00USD
重量
kg
- Product Description
-
rated power 0.75-315 kW
rated voltage 220V/380V/DC 110-440V
insulation class F-level/H-level
Protection level IP54/IP55
working system S1 continuous working system
cooling method IC411 self fan cooling
Description :
Oubang AC/DC asynchronous motor is a power device that converts electrical energy into mechanical energy, widely used in industrial automation, mechanical equipment drive, fluid transportation and other fields. This category of motor combines the advantages of simple structure and easy maintenance of AC motors with the speed regulation performance of DC motors, effectively solving the problem of power output stability under complex working conditions. Typical operating conditions include continuous production lines, packaging machinery that requires frequent start and stop, and fan and water pump systems that have certain speed regulation requirements. As a core product series under Alpa Power Technology Jiangsu Co., Ltd., the OBON AC/DC asynchronous motor aims to provide reliable and efficient power sources for various industrial scenarios, meeting the strict requirements of modern manufacturing industry for equipment energy efficiency ratio and operational stability.
In terms of specifications and processes, Oubang AC/DC asynchronous motors usually use high permeability silicon steel sheets stacked on the stator core to reduce iron loss and improve magnetic flux efficiency. High strength polyester enameled copper wire is commonly used for windings to ensure good insulation performance and heat resistance level. The common insulation level is F or H, allowing for long-term operation at higher ambient temperatures. The shell material is mostly cast iron or aluminum alloy, which has excellent heat dissipation performance and mechanical strength. The protection level usually reaches IP54 or IP55, which can prevent dust accumulation and rainwater splashing from damaging internal components. The implementation standards refer to GB/T 755 Rotating Electrical Machinery Rating and Performance, as well as relevant standards of the IEC International Electrotechnical Commission. Before leaving the factory, strict voltage withstand tests, no-load tests, and load temperature rise tests must be conducted to ensure that every Oubang AC/DC asynchronous motor meets industry standards.
When selecting, it is necessary to clarify the power type, power requirements, speed range, and installation method. Oubang AC/DC asynchronous motors are suitable for applications that require wide range speed regulation or specific torque characteristics. If only constant speed operation and stable power grid are required, ordinary three-phase asynchronous motors may have a cost advantage; If extremely high precision positioning is required, servo motors are more suitable. The advantage of this category lies in its ability to balance the durability of AC motors with the controllability of DC motors, making it particularly suitable for the renovation of old equipment or scenarios that require high adaptability to the power supply environment. When selecting, the purchaser should pay attention to whether the rated voltage is AC or DC input, and whether it is matched with a dedicated driver. For flammable and explosive environments, special models with corresponding explosion-proof certifications should be selected. Conventional OBON AC/DC asynchronous motors are mainly designed for general industrial environments and are not suitable for strong corrosion or extreme high temperature places.
When installing the OBON AC/DC asynchronous motor, it is necessary to ensure that the bottom seat is flat and firm, the coupling or pulley wheel is accurately aligned, and avoid additional radial or axial forces that may cause early bearing wear. The focus of daily maintenance is to regularly check the lubrication condition of the bearings. It is recommended to replenish or replace lithium based grease every 2000-4000 hours of operation. Keep the surface of the motor clean, keep the ventilation ducts unobstructed, and prevent debris from blocking and affecting heat dissipation. Common faults include abnormal noise, overheating, or excessive vibration. Abnormal noise is mainly caused by bearing damage or rotor sweeping, while overheating may be caused by overload, voltage imbalance, or cooling fan failure. Establishing a regular inspection system to monitor changes in operating current and temperature can significantly extend the service life of Oubang AC/DC asynchronous motors, reduce the risk of unplanned shutdowns, and ensure production continuity.
AfterSalesService :
Key words: